background image

 

/ 9 

 E 
 N 
 G 

  

  

 S 
 H 

7

 

PRESSURE 

 

The correct pressure for the buoyancy tube and the AirLite keel is 240 mb / 3,48 PSI, and 800 
mb / 11,3 PSI for the H2P inflatable floor.

 

 

If your boat is not equipped with an 

ACCESS

 pressure indicator, we recommend that you purchase 

one from your Dealer. This will permit a quick and efficient control of the pressure during inflation. 
Without a pressure indicator, stop inflating when the foot-pump gets difficult to operate, and the boat is 
« hard » (you should not be able to bend the cone ends).

 

 

Ambient temperature of air and water 

Ambient temperature 

tubes’ internal pressure 

have an effect on the boat’s internal 

+1°C / +1,8°F 

+4 mb / 0,06 PSI 

pressure 

-1°C / -1,8°F 

-4 mb / 0,06 PSI 

 

Therefore, it is important to anticipate:  

Because of temperature variations (especially when this variation is important between the beginning 
and the end of the day, in hot areas) check and adjust the pressure in the inflated compartments by 
inflating or deflating. Be sure that pressure remains within the recommended pressure , between 220 
mb / 3,10 PSI and 270 mb / 3,85 PSI.

 

 
 

RISK OF UNDERPRESSURE 

 

 EXAMPLE: 

Your boat is in direct sunlight on the beach (temperature =50°C/122°F) at 

recommended pressure (240 mb/3,48 PSI). after putting it in the colder water (temperature 
=20°C/68°F), the internal temperature and pressure of the tubes will both drop (up to         120 mb/1,7 
PSI) and

 YOU WILL HAVE TO INFLATE AGAIN

 until you regain the lost pressure due to the 

difference in temperatures. Therefore, a loss of pressure, at the end of the day when ambient 
temperature drops, is perfectly normal. 

 

NOTICE :

 

Proper inflation is critical to the performance of the boat. It is the pressure in 
the tubes that gives your boat the necessary rigidity to perform well. Under-
inflation causes improper flexing of the tubes which will result in stress and 
chafe 

 
 

RISK OF OVERPRESSURE 

 

 EXAMPLE: 

Your boat is inflated to the recommended pressure (240 mb/3,48 PSI) at the 

beginning of the day (low ambient temperature =10°C/50°F). Later in the day, your boat is in direct 
sunlight on the beach or on a yacht’s deck (temperature =50°C/122°F). Internal temperature of all 
inflated compartments can then increase and reach up to 70°C/158°F (especially for dark-coloured 
tubes). The consequence will be a doubling of previous pressure (480 mb/6,8 PSI).

 YOU WILL THEN 

HAVE TO DEFLATE

 until you reach the recommended pressure. 

 

 

CAUTION

 

WHEN YOUR BOAT IS OVER INFLATED, PRESSURE BECOMES TOO 

STRONG FOR THE INFLATABLE STRUCTURE, AND COULD CAUSE A 

BREAK IN THE FABRIC ASSEMBLY 

 
IN CASE OF OVERPRESSURE 

 

STANDARD VALVE (A): 

Free some air by pushing on the 
diaphragm (1) with a blunt object. 

Beware not to fold down the 
diaphragm.  

 

SEMI-RECESSED OR “EASY 
PUSH” VALVE (B): 

Deflate by pressing the spring 
loaded button

.

 

A

1

 

 

 

Summary of Contents for CADET 240 AERO

Page 1: ...2 Tomo 2 ZT03745 Edition 8 LIRE ATTENTIVEMENT CE MANUEL AVANT LA MISE EN SERVICE DE VOTRE ZODIAC CAREFULLY READ THIS MANUAL BEFORE OPERATING YOUR ZODIAC LEGGERE ATTENTAMENTE PRIMA DE INIZIARE IL MONT...

Page 2: ...OLUME 2 DEALS WITH TECHNICAL SPECIFICATIONS AND ASSEMBLY PROCEDURE OF THE BOAT AND ITS EQUIPMENT VOLUME 2 TECHNICAL SPECIFICATIONS ASSEMBLY PROCEDURE ZODIAC CADET AERO 240 AERO 260 AERO CADET FAST ROL...

Page 3: ...l the seat 8 ASSEMBLY OF EQUIPMENT 8 finish inflation of the boat to the correct pressure 6 7 INFLATION PRESSURE 9 Install the oars 8 ASSEMBLY OF EQUIPMENT CHECK ON UNPACKING CAUTION DO NOT USE A SHAR...

Page 4: ...S LONGITUDINAL CENTERLINE TO ALLOW THE BOX TO BE TURNED TO ITS LOCKED POSITION CAUTION THE BOAT MUST BE DEFLATED FOR THE INSTALLATION THE BOAT MUST NEVER BE INFLATED WITHOUT THE BOX BEING INSTALLED 1...

Page 5: ...ins FIRST inflate the keel floorboard assembly to its rated pressure Check that the keel inflated perpendicular to the floorboard and that it is still positioned on the central band of the bottom othe...

Page 6: ...valve cap Screw the valve support onto its base screw it tight but without exaggeration not to deteriorate the screw thread and check that the valve cap stays accessible TO DEFLATE Unscrew the valve s...

Page 7: ...SI NEVER USE POSITION B TO INFLATE THE MAIN TUBE OR THE KEEL THERE WOULD BE A RISK OF BURST 1 Insert the pump hose end piece add to the semi recessed valve the correct connecting tip 2 Inflate the mai...

Page 8: ...e internal temperature and pressure of the tubes will both drop up to 120 mb 1 7 PSI and YOU WILL HAVE TO INFLATE AGAIN until you regain the lost pressure due to the difference in temperatures Therefo...

Page 9: ...9 8 ASSEMBLY OF STANDARD EQUIPMENT TO ASSEMBLE AND INSTALL THE OARS THE REMOVABLE SEAT Install the seat before the boat is totally inflated Clic...

Page 10: ...3 Remove oars and equipment 4 Empty the boat of all water and sand by opening the self bailers dry it 5 Fold in the 2 sides of the main buoyancy tube fold the cones onto the transom A then fold the b...

Page 11: ......

Page 12: ...1 6 1 6 Capacit Capacity Capacit Kapazit t Capacidad ISO 3 3 1 4 5 6 Maximum Kg 290 370 450 490 750 Lb 639 815 992 1080 1653 Kg 23 25 31 36 39 Lb 51 55 68 79 86 2 1 1 2 1 1 2 1 2 1 3 1 Motorisation O...

Page 13: ...is e avec une extr me prudence voir Tome 1 du manuel chapitre Conseils de navigation La portata massima autorizzata calcolata in conformit alla normativa ISO In condizioni di massimo carico si raccoma...

Page 14: ...tasselli Beiden Niederhalter cu as 11 supports dames de nage rowlock blocks Scalmi basculanti klappbare Ruderdollen soportes chumaceras 12 main courante safety strap tientibene Sicherheitsgurte sangla...

Page 15: ...VI IV DESCRIPTION DESCRIZIONE BESCHREIBUNG DESCRIPCION Cadet Aero 240 Aero 260 Aero 1 2 13 3 4 6 15 9 7 8 14 14 5 12 11 10 18 Cadet Fast Roller Acti V 285 325 1 20 3 4 15 6 9 2 13 14 5 12 11 10 18...

Page 16: ...VI V DESCRIPTION DESCRIZIONE BESCHREIBUNG DESCRIPCION Cadet Fast Roller Acti V 360 Int L 22 1 20 3 4 15 6 9 2 13 14 5 12 11 10 18 21 16 17 15 7 9 18 8...

Page 17: ...IZIONE BESCHREIBUNG DESCRIPCION Cadets Fast Roller Acti V Cadet Fast Roller Acti V Int L Plancher H2P H2P air floor PagliolatoH2P Herausnehhmbarer H2P suelo H2P Cadet Fast Roller Acti V Int L Boite Bo...

Page 18: ...1 Quai de Grenelle 75015 PARIS FRANCE Cadets Aero FR Code ZT03745 Edition 8 Copyright ZODIAC INTERNATIONAL 2009 ZODIAC INTERNATIONAL S A S U au capital de 18 000 000 Euros...

Reviews: