background image

1.1.4 Field of application 

 

 

 

 

 

1.1.5 Operating principle 

 

 

 

1.2 Description 

1.2.1 Technical specifications 

 

Appliance 

Dehumidifying 

capacity* 

Power 

consumed* 

Power restored on 

the ambient air* 

Air flow-

rate 

L/h 

m³/h 

DT 850 

1.88 L/h 

850 W 

2100 W 

500 m

3

/h 

* under the following nominal conditions: air 30°C - humidity 70%. 

 

L/day 

Hygrometry (%HR) 

Ambient temperature (°C) 

55 

60 

65 

70 

75 

35 

43 45 49 54 60 

32 

37 

39 

43 

49 

54 

30 

33 36 40 45 50 

29 

31 

34 

38 

43 

48 

28 

29 33 37 41 46 

27 

27 

31 

35 

40 

44 

26 

25 29 33 38 42 

25 

23 

27 

32 

36 

40 

24 

21 26 30 34 38 

20 

16 

18 

24 

27 

30 

15 

10 14 15 19 22 

 

 unit protection class: IP 44  

 class: I 

 refrigerant gas: 

R407C

  

 refrigerant charge: see product information plate 

 

1.2.2 Operating conditions 

 

 operating range: 7 °C to 35 °C (temperature in the swimming pool hall) 

 optimum operating conditions: between 25 °C and 30 °C 

Exclusive use: dehumidifying swimming pool halls.  
Not to be used for any other purpose. 
It must be installed indoors, in the swimming pool premises, in a location that is not 
subject to freezing and no pool maintenance products should be stored nearby. 

condensation tray 

Dry air 

Moist air 

Compressor 

Fan  

Cooling elements 

condensation outlet 

Air filter 

Summary of Contents for DT 850

Page 1: ...Installation instructions and use DT 850 Air dehumidifier for indoor swimming pools R f N D 009 A EN Ver 05 2010...

Page 2: ...ulations for swimming pools 4 1 3 2 Installation requirements 5 1 3 3 Connection to surrounding air 5 1 3 4 Connection of the condensation drain 6 1 3 5 Electrical connections 6 1 4 Operation 7 1 4 1...

Page 3: ...s The appliance must be transported upright on its pallet The appliance must be transported upright on its pallet in its original packaging If the appliance has been overturned make written reserves i...

Page 4: ...9 33 38 42 25 23 27 32 36 40 24 21 26 30 34 38 20 16 18 24 27 30 15 10 14 15 19 22 unit protection class IP 44 class I refrigerant gas R407C refrigerant charge see product information plate 1 2 2 Oper...

Page 5: ...installed outside volumes 0 1 and 2 the appliance has a protection index of at least IP X5 In volume 2 see figures 702A and 702B the appliances must be either class II for lighting or class I protecte...

Page 6: ...the walls are sufficiently waterproofed and insulated to avoid condensation forming in the room when relative humidity reaches 60 to 70 Light structure buildings verandas shelters there is no risk of...

Page 7: ...ying with the standards and regulations in force in the country where it is installed in France standard NF C 15100 use the supply cable delivered with the appliance 2 poles Earth 10 16 A in 3G1 5 sec...

Page 8: ...ycle is controlled and triggered by an Alpha 14 1 electronic module that monitors the state of the evaporator sensor probe S IN every 20 minutes the compressor stops for 8 minutes maximum and the cond...

Page 9: ...ommunity association which will be able to repair it and put it back into circulation If you buy a new appliance you can take the old one back to the reseller or ask the transporter to take it back Th...

Page 10: ...1 Electrical diagram DT 850...

Page 11: ...st clock S1 Condenser probe S2 Evaporator probe VO Under voltage light CR Plug connector Ml Male plug Fl Female plug I1 Fan speed selector H Hygrostat THS Compressor safety thermostat BA Power supply...

Page 12: ...Care Europe Boulevard de la Romanerie BP 90023 49180 Saint Barth l my d Anjou cedex France www zodiac poolcare com Global provider of innovative pool products and services Produits et services innova...