10
Connecting the Communication Cable
1.
Remove the DuoClear power pack cover and connect the 4-conductor communication cable to the
“eos com” terminal block on the DuoClear control PCB, mounted in the DuoClear cover. The wiring
configurations for the various controllers are shown below:
Polaris Eos
Jandy Aqualink RS
Pentair IntelliTouch
Note: The wiring configurations are
the same for Jandy Rev K and Rev L
controllers.
Note: When connecting to the Jandy
Aqualink RS controller with Rev L, the
DuoClear will appear in the settings
menu as an "AquaPure" chlorinator.
2.
Fit the communication wire into
the slot on the transformer side of
the main panel.
3.
Route the cable around the
transformer as shown and secure
it in two places with clips.
Interface for Automation System Controllers
Since the DuoClear can be connected to several different controllers, it is necessary to select and setup
an interface for the specific unit controlling the unit.
1.
Turn on power to the DuoClear and
pump via the controller.
2.
Press the SERVICE button (hidden to the
right of the ON/OFF button) down for at
least 20 seconds while observing the
green SUPER CHLORINATE light. The
LED will flash momentarily, either 1, 2
or 3 times, then go out for approximately
5 seconds.
DuoClear Control PCB
Communication Terminal Block
Red
Green
Yel/White
Black
Black = (A)
Yel/White = Signal- (B)
Green = 0V
Red = V+
Black = (A)
Yel/White = Signal- (B)
Green = 0V
Red = V+
DuoClear Control PCB
Communication Terminal Block
Red
Black
Green
Yel/White
Black = 0V
Yel/White = (A)
Green = Signal- (B)
Red = V+
DuoClaar Control PCB
Communication Terminal Block
Red
Green
Yel/White
Black
Hidden
SERVICE
Button
Clips
Communication
Cable
Summary of Contents for DuoClear
Page 1: ...Complete In Ground Pool Sanitizing System Installation Guide and Owner s Manual...
Page 4: ......
Page 6: ......
Page 23: ......