12
Chlorine Reading is Too High
Do the output lights go up and down?
YES
NO
Reduce output setting.
Check touch pad PCB.
(see Touch Pad PCB pg. 14)
Replace power PCB.
(see Touch Pad PCB pg. 14)
Reduce pump run time.
Check pH.
(per test kit instructions)
Check calcium hardness.
(per test kit instructions)
Clean cell manually.
(see pg. 13)
Calcium Build-up on Cell
Is chlorinator reversing polarity properly?
Press and hold service button
(located 1” to the right of the ON/OFF switch
and the Nature2 Reset switch)
to speed up the reversing process.
(see Reversing Polarity pg. 13)
YES
NO
Check touch pad PCB.
(see Power PCB pg. 16)
Note:
New plaster pools will have a
continuous demand for acid for 6 months
or more .
High pH conditions and/or high calcium
hardness levels will make scale build-up more
likely . Maintain a pH between 7 .2 and 7 .6 .
Summary of Contents for DuoClear