11
EN
•
Open the electrical compartment
in front of the
user interface by unscrewing the screw and lift ing
the cover.
•
Unscrew the 6 screws securing the user interface to
the pump.
•
Unscrew the 4 wires from the user interface terminal
board .
•
Disconnect the RS485 terminal board
and put it
aside.
•
Unscrew the cap and install a cable gland to pass the
RS485 cable out of the electrical compartment.
•
Provide the correct length of cable for the extension
and connect it to the RS485 terminal board , then
connect it inside the electrical compartment
.
•
Fit the cover and the foam gasket in the positi on of
the user interface on the pump using the 6 screws
.
•
Drill a hole in the positi on marked in the centre of the
base
, then install the grommet
.
•
Secure the wall mount
onto a stable wall (using
screws suited to the support, not supplied), away from
humidity and direct sunlight.
•
Connect the other end of the RS485 cable
to the
user interface terminal board
.
•
Att ach the user interface onto the base using its
6 screws.