3.3 I Operati on
• To prevent against any risk of explosion that may cause material damage, serious injury or
even death, make sure that the hydraulic circuit is free of any debris or blockage and is not
subject to excessive pressure.
• Never run the pump "dry" as this may damage it.
• The pre-fi lter strainer cover must be closed by hand (do not use tools).
•
Check that the hydraulic connecti ons are correctly ti ghtened.
•
Check that the pump is stable and level.
•
The hydraulic circuit must be bled and not contain any foreign bodies.
•
The pump pre-fi lter strainer cover must be correctly closed (by hand) and its gasket clean and in place.
•
Check that the valves are open.
•
Start a speed; the pump always starts in "priming" mode (high speed).
•
The pump is self-priming. However, it is strongly recommended that you fi ll the pre-fi lter strainer with water before
starti ng it up for the fi rst ti me to facilitate the procedure.
•
The pump has a priming capacity up to 3 metres above the swimming pool water level and at sea level elevati on (if
the hydraulic circuit is perfectly sealed).
•
Bleed any air present in the fi ltrati on circuit using the bleed normally present on the fi lter (refer to the swimming pool
fi lter's manual).
•
Check that there are no leaks on the hydraulic circuit.
3.4 I User functi ons (model with interface only)
3.4.1 Locking and unlocking the keypad
•
Press and hold
and
for 5 seconds:
is displayed as long as the keypad is
locked.
•
To unlock, press and hold
and
for 5 seconds; the message disappears.
3.4.2 Starti ng or stopping a speed
Speed
Keys to start or stop a speed
Default speed
"eStar" speed
1,750 rpm
Speed 2
2,750 rpm
Speed 3
2,750 rpm
Speed 4
2,750 rpm
Speed 5, 6, 7 or 8
then
or
then
to confi rm
2,750 rpm
Priming speed
Automati c at start-up
2,750 rpm for 3 minutes
•
When the pump is running, it displays
(speed No. and name, ti me, operati ng
speed), and an LED lights up over the key corresponding to the speed.
•
For speeds 2, 3, 4, 5, 6, 7 and 8, you can change the default speed by pressing
or
when the speed is running
(from 600 to 3,450 rpm). Any changes made are automati cally saved.
•
To set the "eStar" default speed, see § "3.6 I Additi onal functi ons for professionals only (model with interface only)".
•
To stop the pump, press the key for the current operati ng speed (
, ,
or
), or press
(speeds 5, 6, 7
or 8).