Page 25/68
E
N
G
L
I
S
H
BUOYANCY CHAMBER - Pressure
II-4-1-Inflating the buoyancy chamber
•
Place the adapter corresponding to the diameter of the semi built-in valve at the inflator
hose nozzle.
Inflate the buoyancy mechanism,
balancing the pressure between the different
compartments until the partitions (a) are no longer visible (pressure = 240 mb)
Never pressurise a
compartment when the
others are completely
deflated
a
1
2
Inflating is complete:
Screw on the inflating valve caps
NOTE:
A slight air leak is normal before the valve cap is screwed on
Only the caps guarantee final air tightness.
II-4-2-Pressure
The correct pressure for the buoyancy chamber is 240 mb/ 3.4 PSI
The ambient temperature of the air or
water proportionately influences the
level of internal pressure in the
buoyancy chamber
Ambient temperature
Buoyancy chamber
internal pressure
+1°C
+4 mb / 0.06 PSI
-1°C
-4 mb / 0.06 PSI
Summary of Contents for NZO 700
Page 1: ...Page 1 68 E N G L I S H Owner s Manual Volume 2...
Page 32: ...Page 32 68 INSTALLATION AND CIRCUIT Electricity IV 2 Electricity IV 2 1 Layout diagram...
Page 62: ...Page 62 68 LABELLING V 2 DESCRIPTION OF SAFETY LABELS AND REGISTRATION PLATES 1 4 3 2...
Page 66: ...Page 66 68 LOCATION OF OPTIONAL ACCESSORIES VI 3 PLOTTER VHF not supplied VHF Plotter...