1.3 I Accessing the electrical terminal blocks
Unscrew the 3 screws on the
technical access door at the rear of
the appliance.
Remove the technical access door.
Pass the cables through the cable
glands on the technical access door.
1.4 I Power supply connections
• Before any work inside the appliance, you must cut the appliance’s electricity supply as there
is a risk of electric shock which may cause material damage, serious injury or even death.
• Incorrectly tightened terminals may cause the terminal box to heat up, which can invalidate
the warranty.
• Only a qualified and experienced technician is authorised to carry out cabling work within the
appliance or to replace the power cord.
• The installer must consult the electricity provider if necessary and ensure that the equipment
is connected correctly to an electricity network with impedance under 0.095 ohm.
•
The heat pump's electrical supply must be provided through a protection and circuit breaking device (not supplied)
complying with the standards and regulations in force in the country where it is installed.
•
The appliance is provided for connection to a general power supply with a TT or TN-S neutral regime.
•
Electrical protection: by circuit breaker (D curve, rating to be defined according to the table in § “5.2 I Technical
specifications”), with a suitable dedicated residual-current device (circuit breaker or switch).
•
Additional protection may be required during installation to guarantee the overvoltage category II.
•
The power supply must correspond to the voltage indicated on the appliance's information plate.
•
The power cord must be insulated against any cutting or hot elements that may damage or crush it.
• The appliance must be connected to an earth socket.
•
The electrical connection lines must be fixed.
• Use the gland to pass the power cord into the appliance.
•
Use the power cord (RO2V type) adapted for outdoor or buried use (or run the cable into a protection duct) with an
external diameter of between 9 and 18 mm.
•
We recommend burying the cable at a depth of 50 cm (85 cm under a road or path) in an electrical duct (red ribbed).
•
If this buried cable meets another cable or pipe (gas, water, etc.), there must be more than 20 cm between them.
• Connect the power cord to the terminal block inside the appliance.
L: live
N: neutral
: earth
A/B/C: live
N: neutral
: earth
Terminal block for single-phase power
Terminal block for three-phase power