WARNING
Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment
to fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment.
WARNING
To minimize risk of severe injury or death the filter and/or pump should not be subjected to the piping
system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements
are generally not intended to apply to the pool equipment such as filters or pumps.
Zodiac
pool equipment is pressure tested at the factory.
If however the WARNING cannot be followed and pressure testing of the piping system must include the
filter and/or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed
and secured before testing.
• RELEASE ALL AIR
in the system before testing.
• Water pressure for test must NOT EXCEED 35 PSI (241 kPa).
• Water temperature for test must NOT EXCEED 100°F (38°C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
• Notice
: These parameters apply to Zodiac equipment only. For non-Zodiac
equipment, consult equip
-
ment manufacturer.
SAVE THESE INSTRUCTIONS