background image

1. Installation 

1.1 General 

Read this manual carefully before installing, maintaining or repairing this appliance! 

The 

 symbol indicates important information that must be taken into account in order to 

avoid the risk of injury and/or damage to the appliance. 

The  

 symbol indicates useful information.

 

 

1.1.1 Precautions 

 

 

 

 

 

 

 

 

 

1.1.2 General terms of delivery 

 

Any equipment, even CARRIAGE and PACKING FREE, travels at the recipient’s risk. The recipient 
must indicate any reserves in writing on the carrier's delivery bill in the case of damage caused during 
transport (confirmation to be sent to the carrier within 48 hours by registered mail and 
Acknowledgement of Receipt). 

 

 

 

Contents: 
 

       

+

   

 

      

+

  

  

 

+

   

 
 
 

 

 
 

 

 

 

 

 
 

Supplied parts:

  

 

Hygro Control 

+

 

 anti-vibration studs x4 

 

 dowel x 2 

 long bolt x 2 

For Sirocco can be inset : 

 sleeve x 2 + 

 frame with cadre suction grid and filter x 1 + 

 frame 

with blowing grid + 

 frame fixture kit x 1 

The appliance must be transported upright on its pallet, in its original packaging. 

If the appliance has been overturned make written reserves in writing to the transporter. 

Removing or shunting any of the safety or remote control parts will automatically 
void the guarantee; the same will apply for the replacement of parts by non-
original parts. 

Do not discharge R407C fluid into the atmosphere: R407C is a fluorinated 
greenhouse effect gas, covered by the Kyoto Protocol, with a Global Warming 
Potential (GWP) = 1653 - (Directive EC 842/2006).

 

Before working on the appliance, ensure that it is disconnected from the power 
supply.  

This device must be installed and serviced by certified professionals approved in 
the electrical, hydraulic and cooling domains.  

 

 

 

 

 

 

EN 

Summary of Contents for SIROCCO 110

Page 1: ...Installation instructions Air dehumidifier for indoor swimming pools R f N D 005 A EN Ver 02 2010 SIROCCO 55 80 110...

Page 2: ...to surrounding air 6 1 3 5 Inset connection 7 1 3 6 Connection of the condensation drainage 8 1 3 7 Electric connections 8 1 3 8 Connection of the options 12 1 4 Commissioning 13 1 4 1 Starting the a...

Page 3: ...on studs x4 dowel x 2 long bolt x 2 For Sirocco can be inset sleeve x 2 frame with cadre suction grid and filter x 1 frame with blowing grid frame fixture kit x 1 The appliance must be transported upr...

Page 4: ...0 unit protection class Sirocco ambient IP 44 Sirocco can be inset IP 45 class I refrigerant gas R407C refrigerant charge see product information plate 1 2 2 Operating conditions operating range 10 C...

Page 5: ...installed outside volumes 0 1 and 2 the appliance has a protection index of at least IP X5 In volume 2 see figures 702A and 702B the appliances must be either class II for lighting or class I protecte...

Page 6: ...hat the materials used are compatible with a swimming pool environment the walls are sufficiently waterproofed and insulated to avoid condensation forming in the room when relative humidity reaches 60...

Page 7: ...with two bolt screws washers and plugs supplied in a solid wall Pool minimum distance Sirocco 55 80 110 suction grid blowing grid Hygro Control condensation drainage air renewal system see 1 3 2 fres...

Page 8: ...leeves and mark the two inside anchoring points install the fixing plugs into the solid wall using the marks present the appliance again and from the inside screw in the bolt screws washers into each...

Page 9: ...7 3 Cable sizes Supply cable size for cables of a maximum length of 20 metres calculation basis 5A mm this must be checked and adapted depending on installation conditions Option Voltage Nominal powe...

Page 10: ...echnician must install the device cables If the power cable is damaged it must be replaced by a qualified technician or by a Zodiac Pool Care Europe service station Main supply see 1 3 7 3 Regulation...

Page 11: ...desired relative humidity Display of the ambient temperature and or humidity by pressing once C and or RH blink To exit press or wait 10 seconds only if your appliance is fitted with the hot water ba...

Page 12: ...ll the digits light or and the appliance starts up Parameter setting in hygro thermostat or hygrostat mode Hygro Control must be on standby press and for 3 seconds hygro thermostat mode press or to se...

Page 13: ...nput to the hot water battery 45 C minimum 90 C maximum Maximum pressure water battery circuit 3 bars Power returned to the air at 27 C input to the hot water battery Connection to the primary circuit...

Page 14: ...s a heating request is active This safety device has two levels of triggering 1 by THS safety thermostat if the T C is 65 C it is automatically reset 2 if the temperature continues to increase the sec...

Page 15: ...e thermostat function request active if 6Vac 50Hz between 2 and 4 8 input 12Vac 50Hz fan heat fault shunted not active fault active if 0Vac 50Hz between 8 and 4 d faut thermique ventilateur led lit up...

Page 16: ...emperature than 5 C or than 40 C a defrosting cycle is in progress temperature is 5 C The compressor is stopped and ventilation is maintained the defrosting sensor is out of order The defrosting cycle...

Page 17: ...ol and make a shunt between terminals 1 5 7 and check the voltage between 4 5 12V Replace the ECP 600 no yes Replace the Hygro Control See faults table 2 1 The appliance does not work No fault display...

Page 18: ...o Is the appliance being ventilated all the time Voltage on the compressor terminals 230V or 400V yes Replace the contactor no no Re connect the Hygro Control and check that it is operational Wait for...

Page 19: ...teries evaporator condenser and hot water by removing the cover from the appliance switched off Depending on the condition clean with a silk brush and a vacuum cleaner 3 2 Spare parts Naming Item numb...

Page 20: ...e back to the reseller or ask the transporter to take it back This is known as a One for One exchange Otherwise please take it to a waste collection centre if your local council has set up a selective...

Page 21: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Page 22: ...1 Electric diagram Sirocco 55 80 110 single phase...

Page 23: ...2 Sirocco 110 three phase...

Page 24: ...y 230Vac 50Hz for battery circulator or used for electric logic of the heating option by electric backing E1 high pressure switch E2 low pressure switch OAE back up heating option R heating resistor T...

Page 25: ...4 Dimensions weight without option A B C Kg mm Sirocco 55 65 1030 620 653 Sirocco 80 75 1220 810 843 Sirocco 110 85 1410 1000 1033...

Page 26: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Page 27: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Page 28: ...Care Europe Boulevard de la Romanerie BP 90023 49180 Saint Barth l my d Anjou cedex France www zodiac poolcare com Global provider of innovative pool products and services Produits et services innova...

Reviews: