7
1.3.5 Inset connection
Install the appliance in a technical room that is protected from freezing.
Reserve dimensions (+2 mm / -0 mm)
mm
Sirocco 55
618 x 165
Sirocco 80
808 x 165
Sirocco 110
998 x 165
the sleeves are:
- to be incorporated in the wall at the time of construction,
- or for sliding into the previously made reservations in the wall, plan for a gasket between the
wall and the outside surface of each sleeve of the technical room and swimming pool room side,
present the base of the appliance (without the cover) to the wall, opposite the sleeves and mark
the two inside anchoring points,
install the fixing plugs into the “solid wall” using the marks,
present the appliance again and from the inside screw in the bolt- washers into each plug
plan for an earth for the blowing and suction grid frame, following the electrical standards in force
in the country (in France: standard NFC 15100, see §1.3.1).
At this moment, the frames fixed to the back of the appliance must easily slot into each
sleeve.
The blocks of polystyrene must remain in the sleeves to protect them from
crushing.
Pool
* minimum distance
** maximum distance
Sirocco 55-80-110
suction grid
blowing grid
Hygro Control
condensation drainage
air renewal system (see §1.3.2)
fresh air intake
Technical
room
Swimming
pool
hall
Summary of Contents for SIROCCO 110
Page 21: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Page 22: ...1 Electric diagram Sirocco 55 80 110 single phase...
Page 23: ...2 Sirocco 110 three phase...
Page 26: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Page 27: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...