1.5 Technical information

  

 

Control unit voltage

 

220-

240 VAC, 50 Hz;

 short-circuit-

proof

 

safety isolating type

 

Robot supply voltage

 

30 VDC

 

Insta

lled load 

150 

W

 

Cable length

 

18 

 

Cleaner

 

size (WxDxH)

 

43 x 48 x 27

 

cm

 

Pack size (WxDxH)

 

58 x 58 x 59

 

cm

 

Weight of cleaner

 

11 

kg

 300 

Packed weight

 

19

 

kg

 

Filtering surface

 

3400 cm²

 

Filtration 

 

medium

 

Theoretical width cleaned

 

38 

cm

 

Theoretical area cleaned

 

260 m² / h

 

Pump output

 

16 

m³/h

 

Rate

 

m / min

 

 

2. Use 

 

2.1 Advice on use 

 

 

The cleaner must operate in pool water maintained at the following levels: Chlorine < 3 mg, pH between 6.8 and 
7.6, temperature between 10°C and 35°C.

 

 

Use your cleaner as often as possible. You will benefit from a pool that is always clean and the filter will not 
become clogged.

 

 

If the pool is very dirty, especially during first use, remove larger pieces of debris using a net in order to optimise 
the cleaner's performance.

 

 

Remove thermometers, toys and other objects that might damage the cleaner from the water.

 

 

Immerse the cleaner in the pool, before starting a cleaning cycle.

 

 

Do not leave the cleaner in the water permanently.

 

 

Stow your cleaner on its caddy as soon as possible after use, in order to avoid distorting the flexible edge at the 
opening to th

e filter. 

 

Never cover 

the control box while the cleaner is in operation

 

 

Do not leave the control box in direct sunlight after having used the cleaner.

 

 

If part of the pool is not properly cleaned, change the place where you immerse the cleaner until you fin

d the 

best position of entry to achieve the best coverage.

 

 

The cleaner's behaviour is strongly influenced if the cable is tangled. Spread the cable out in the sun from time 
to time so that it resumes

 

its original shape.

 

 

The behaviour of the cleaner can be influenced by the jet at the pool return outlets especially when the filter 
pump  is  operational.  In  this  case  we  recommend  that  you  start  your  cleaner  when  the  filter  pump  is  not 
operational.

 

 

2.2 Immersing the robot 

 

 

Submerge the cleaner in the pool and remove any air trapped inside

 

by keeping the unit vertical 

(1).

 

 

Ensure the unit sinks to the bottom of the pool 

(2).

 

 

Spread out the floating cable over the pool, ensuring there are no kinks or coils in the cable 

(3).

 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 

Do not use your cleaner during shock chlorination! 

 

 

 

Summary of Contents for V3

Page 1: ...EN...

Page 2: ...er to the installation instructions relating to the swimming pool equipment for which the cleaner will be an integral part The cleaner is to be supplied through a Residual Current Device RCD with a ra...

Page 3: ...before removing it from water and do not operate out of water Do not remove the cleaner from the pool for 15 minutes after the cleaning cycle has completed Clean filter canister in the cleaner after e...

Page 4: ...n the cart as shown 1 Make sure the upper tubes handles are in the proper orientation and align the screw holes Position the bottom power cable hook as shown 2 Place the cable hook plate opposite the...

Page 5: ...s to the caddy using four screws V3 figure 9 V3 4WD figure 10 The transport caddy is now ready to use 1 4 Connecting the control unit to the caddy Position the control unit over the control unit hook...

Page 6: ...re starting a cleaning cycle Do not leave the cleaner in the water permanently Stow your cleaner on its caddy as soon as possible after use in order to avoid distorting the flexible edge at the openin...

Page 7: ...When the cleaner is powered ON it will remain in standby until the Cycle I button is pressed 1 When the Cycle I program button is selected the indicator light above will illuminate The cleaner will s...

Page 8: ...t the cover 2 until it is secured in the vertical position Figure 1 Remove the filter assembly from the body 3 Figure 2 Push the quick release button on the canister assembly 4 and pull open the filte...

Page 9: ...es as soon as one of the wear indicators has been reached even if the blade wear is not even It recommended to replace the brushes every two 2 years Lift the cleaner to a vertical position so that the...

Page 10: ...s appear just after start pressing the Power or Cycle button to start the cleaner 20 seconds Floating cable is not properly plugged into the control unit Unplug the floating cable from the control uni...

Page 11: ...trike Symptom Cause Solution The cleaner does not stay firmly on the pool bottom There is air in the appliance casing Submerge the cleaner following the procedure in Section 2 2 Submerging the Cleaner...

Page 12: ...and obtain a warranty ID number for the warranty claim Contact details are Zodiac Group Australia Pty Ltd Customer Service 219 Woodpark Road Telephone 1800 688 552 Smithfield NSW 2164 Email address a...

Page 13: ...Notes...

Page 14: ...Notes...

Page 15: ...Notes...

Page 16: ......

Reviews: