H0548500.A - EN - 2015-11
7
2.4 I Opti on connecti on
2.4.1 "Heati ng priority" opti on (depending on model)
•
This functi on helps to keep the water temperature constant by checking the water temperature at regular ti me
intervals (minimum 5 minute cycle every 220 minutes (modifi able ti me)) by fi ltrati on pump control. The fi ltrati on is
kept operati ng while the pool temperature is below the temperature requested.
•
For the connecti on, connect the fi ltrati on ti mer to terminals 1 and 2 and add a shunt between terminals 3 and 4.
1
2
1-
2 : power for the fi ltrati on pump power contactor coil
: fi ltrati on ti mer
: power contactor (tripolar or bipolar) for the fi ltrati on system
pump motor
: separate cable for the "heati ng priority" functi on
: heat pump terminal (see wiring diagram § “5.3 I Wiring
diagrams”)
: fuse
•
Modifi cati on of the ti me between 2 fi ltrati on operati ons (value in number of minutes):
- press
and
or
at the same ti me for 3 seconds:
appears,
- press
unti l the
parameter appears, then press
or
to change the parameter using
the
and
keys.
-
Once the value has been modifi ed, press
or
to confi rm,
- press
to exit the menu.
2.4.2 "Remote control" opti on (depending on model)
•
This opti on enables the device's user interface to be duplicated to enable the device to be controlled by remote. To
do so, use the remote control kit available as an accessory.
•
For the connecti on, consult the manual supplied with the kit.