INFLATION SYSTEM
The inflation system is composed of:
THE HIGH PRESSURE FOOT-PUMP FOR MODELS WITH AN INFLATABLE AEROTEC FLOOR
A
B
Position A
The pump has maximum flow but low
pressure: this position is used to give
shape rapidly to all inflatable parts of
the boat.
Position B
The flow is inferior to position
A,
but
provides pressure that is superior, with
the same effort.
Position C
To deflate. Insert the tube as indicated
in figure C and pump normally.
C
THE STANDARD INFLATOR – EXCEPT FOR AEROTEC MODELS.
A. tube nozzle
B. tube connector
C. inflation port
A
B
C
1/4
THE VALVES .
To change the position:
Inflation position
Deflation position
Push / Push
diaphragm closed, the inner
button springs upwards
diaphragm open, the inner
button goes down