© Copyright 2002 Zoeller Co. All rights reserved.
7
19. Typical installation using flexible, high pressure hose provided with unit.
20. Press 1/2” I.D. rigid or non-collapsible plastic tubing (not included) onto drain line
hose barb until snug and secure with a hose clamp. (Not included.) NOTE: Do not
run 1/2” drain line over 8 feet vertically or 20 feet in length. If over 20 feet, 3/4” tube
is recommended.
21. Typical drain line ran into stand pipe with proper 4” air gap. NOTE: An air gap is
required by most local plumbing codes to prevent waste water back flow. Check and
follow your local codes.
22. Install 1/2” I.D. rigid or non-collapsible tubing (not included) to the overflow hose
barb located on the back of the softener brine tank and run to a drain located below
the level of the hose barb.
23. Plug cord from control valve into a 115V grounded electrical outlet. Make certain
that outlet is supplied with power at all times. Make sure area is dry before plugging
the unit in.
24. Open main water supply shut-off valve. CHECK FOR LEAKS! Close previously
opened faucet (step 15).