TANK TO HOUSE CONNECTION

1.  Most pressure tanks will have a 1 inch inlet elbow 

on the bottom. Connect to this elbow with a  1 in. 

MPT x 1 in. slip (glue) adapter and short piece of 

pipe (Fig. 1).   

2.  Install a 1 inch elbow (Fig. 2).   

3.  Attach a 1 in. slip (glue) x 3/4 in. FPT adapter and 

3/4 in. MPT x 3/4 in. slip (Fig. 3).

4.  Install a 3/4 in. union (optional) and continue with 

pipe and 3/4 in. x 3/4 in. x 3/4 in. tee (Fig. 4).

5.  Make the connection to the house plumbing. 

From the tee, install pipe (Fig. 5) and shut off 

valve (optional).

6.  Completed installation with piping and tank is shown 

(Fig. 6).

7. Optional tank-mounted system is shown.   

 

  Connections are basically the same as explained in  

  previous steps. (Fig. 7)

IL1365

1

Glue

IL1366

2

Glue

IL1367

3

Glue

IL1368

4

Glue

IL1386

6

IL1369 

5

Glue

To House

L1

L2

A

B

L1

L2

A

B

115 Volts

Single Phase

Line

230 Volts

Single Phase

Line

Y
E
L
L

O

W

W

H

I

T
E

G

R
E
Y

R
E

D

T

A
N

Y
E
L
L

O

W

W

H

I

T
E

G

R
E
Y

R
E

D

T

A
N

Check Voltage of Power Source

Before Connecting

DO NOT CONNECT ANY GROUND WIRE 

TO THESE LEADS

WIRING DIAGRAM

Wiring The Pressure Switch

1.CAUTION:  Make certain that the power source matches the pump requirements.  This pump can  

  run on 115V or 230V.  See pump label for voltage prewired at the factory. (Fig. 1)
 NOTE:  To change Pump voltage, see wiring diagram on this page or step-by-step instructions on  

  page 11.
  Your pump motor has a built-in thermal overload that protects the motor against burnout from    

  overload of low voltage, high voltage, and other causes.  The device is automatic and resets itself  

  once the temperature has dropped to a safe point.  Frequent tripping of the device indicates trouble  

  in the motor or power lines and immediate attention is needed.

  CAUTION: 

 All wiring should be performed by a qualified electrician in accordance with the 

National Electric Code and local electric codes.  Connect the pump to a separate electrical circuit with 

a dedicated circuit breaker. Refer to the Wire Size Chart for proper fuse size.  Protect the power cable 

from coming in contact with sharp objects.  Make certain that the power source matches the pump 

requirements.  This pump has a dual voltage motor and can run on 115V or 230V. 1/2 HP pumps are 

wired from the factory to run on 115V. 1 HP pumps are wired from the factory to run at 230V.

  WARNING:  The pump must be properly grounded using the proper wire cable with ground.  

Always disconnect pump from electricity before performing any work on the motor.

Under-size wiring can cause motor failure and even fire. Use proper wire size specified in the Wire 

size chart.  Replace damaged or worn wiring cord immediately.  Do not kink power cable and never 

allow the cable to come in contact with oil, grease, hot surfaces, or chemicals.

PUMP ELECTRICAL CONNECTIONS

IL1401

1

IL1365

IL1366

IL1367

IL1368

IL1369

IL1386

IL0924

IL1401

IL1371

7

Summary of Contents for NE462

Page 1: ...be followed THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP MAINTAIN ALL SAFETY DECALS Table of Contents Safety Instructions 1 Limited Warranty 2 Preinstalla...

Page 2: ...IAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESS...

Page 3: ...by wiring the unit to a ground metal clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means 6 Hazardous Pressure Install pressur...

Page 4: ...and in accordance with local and state codes PIPING 1 Old or badly scaled pipe should not be used because dislodged flakes of scale can cause stoppage of the ejector nozzle and malfunction the entire...

Page 5: ...tion 1 Ball Valve plastic 2 3 4 in x 1 4 in bushing steel 3 Pressure Gauge 4 Pump stand for tank 5 Well adapter for single pipe packer installations straight and right angle shown NOTE For a successfu...

Page 6: ...e Pipe System Where water level is greater than 25 feet and inside diameter of well is 4 or larger 1 Attach the foot valve to the ejector using a galvanized steel or plastic nipple Add enough 1 in pre...

Page 7: ...d check for leaks by pouring water into the suction pipe 4 Attach well adapter to suction pipe lower over casing top and tighten adapter flange 5 If no leaks are found proceed to WELL TO PUMP CONNECTI...

Page 8: ...ll with additional pipe and fittings as needed Fig 5 Shallow Well Application Only CAUTION Dry fit entire assembly to ensure proper fit before gluing or taping parts Follow all proper gluing procedure...

Page 9: ...7 5 Glue Deep Well Application Only 1 To begin the connection to the pressure tank loosely assemble flow control body to pump head Using Teflon tape position the discharge outlet of the control body f...

Page 10: ...on this page or step by step instructions on page 11 Your pump motor has a built in thermal overload that protects the motor against burnout from overload of low voltage high voltage and other causes...

Page 11: ...y through the strain relief and tighten both screws on the strain relief Do not crush wire Fig 7 8 Connect the two wires from the power supply to the two outside terminals on the pressure switch Fig 8...

Page 12: ...ming voltage matches the pump wiring voltage See wiring guide in the instructions NOTE Watch for leaks or a milky color in the discharged water which indicates an air leak Make sure foot valve and or...

Page 13: ...the pump is being used for shallow well applications the flow control screw should be set in the full open position IMPORTANT If the pump fails to prime within five minutes Turn power off at the break...

Page 14: ...of liquid soap to the inside diameter of the rubber drive ring 7 Replace the impeller and diffuser removed in Steps 2 3 8 Reassemble the pump body to the motor and mounting bracket MOTOR REPLACEMENT...

Page 15: ...ng Ring Square Cut Seal Rotary w Spring Impeller Diffuser Rubber Diffuser Control Assembly Control Body Flow Control Screw Pump Body Plug 1 4 NPT Pressure Switch Cap Screws 3 8 x 3 4 Base Lead Wire 1...

Page 16: ...pany 2 Reprime if necessary 3 Rearrange piping to eliminate air lock 4 Replace undersized piping or install pump with higher capacity 5 Tighten all fittings and replace control if necessary 6 Make sur...

Reviews: