background image

14

© Copyright 2015 Zoeller

®

 Co. All rights reserved.

SEAL ASSEMBLY AND MOTOR REPLACEMENT

ROTARY SEAL ASSEMBLY REPLACEMENT 

CAUTION

 Make certain that the power supply is 

disconnected before attempting to service the unit!  The rotary 

seal assembly must be handled carefully to avoid damaging 

the precision lapped faces of the sealing components.

1.   Disengage pump body (Ref. No. 10) from motor mounting ring 

(Ref. No. 2).

2.   Remove diffuser (Ref. No. 6).
3. To remove the impeller use a 9/16" open end wrench to hold the 

motor shaft.  On Uni-frame motors, remove the rear cover, the 

flat area is located between the governor and rear bearing.  On 

Nema J motors, the shaft flat area is located in the middle of 

the mounting ring.  Uni-frame or Nema J motors are indicated 

by 56U or 56J respectively in the frame "FR" block on the motor 

decal.

4.   The rotary seal (Ref. No. 4) will come loose at this time.  Use a 

screwdriver (or similar instrument) to pry the ceramic seal and 

rubber gasket from the recess of the mounting bracket.

   

CAUTION

 Be careful not to damage the motor shaft 

or recess surface.

5.   Clean the recess and motor shaft thoroughly.
6.   Install the new rotary seal assembly. 

     a.   Insert the ceramic seal and the rubber gasket into the recess.

NOTE:  To help facilitate installation, apply a drop of liquid soap to 

the outside diameter of the rubber gasket.  Make certain that the 

ceramic seal is kept clean and free of dirt and/or oil. 

     b.   Slip the remaining parts of the rotary seal assembly onto the 

motor shaft.

NOTE:  Apply a drop of liquid soap to the inside diameter of the 

rubber drive ring.
7.   Replace the impeller and diffuser removed in Steps 2 & 3.
8.   Reassemble the pump body to the motor and mounting bracket.

MOTOR REPLACEMENT (Figure 5)

1.   Uni-Frame motors can be replaced in the field with any standard 

Nema J jet pump motor by following the instructions below.

CAUTION

 Before attempting to replace the motor, 

make certain that the power supply is disconnected and the 

system pressure is relieved.

2.   Remove pump body (Ref. No. 10), diffuser (Ref. No. 6), impeller 

(Ref. No. 5), and shaft seal (Ref. No. 4) by following steps 1, 2, 3 

& 4 of Rotary Seal Replacement.

3.   Uni-Frame motors (indicated by 56U in the frame “FR” block on 

the motor decal) can be removed as follows: 

     a.   Disassemble pump base (Ref. No. 14) from unit by removing 

two (2) 3/8” hex nuts. 

     b.   Remove four (4) thru bolts from rear of motor and pull away 

shell and stator assembly (discard). 

     c.   Disconnect four (4) self tapping screws that hold the bearing 

housing to the mounting ring.  Discard bearing housing, rotor 

assembly and (2) square headed screws.

4.   Replace motor with standard Nema J jet pump motor by 

positioning motor against the mounting frame and assembling 

with four (4) 3/8” x 3/4” cap screws.  The mounting base is 

connected at the bottom of the mounting frame with two (2) of 

the four (4) 3/8” x 3/4” cap screws.

5.   Follow steps 5, 6, 7 and 8 of Rotor Seal Assembly to reassemble 

the remainder of the pump.  Because damage to the shaft seal is 

most likely to occur in disassembly, a new seal will be necessary.

NOTE:  The pumps and motors require no lubrication.  The ball 

bearings of the motor have been greased at the factory and under 

normal operating conditions should require no further greasing.

Summary of Contents for NE462

Page 1: ...be followed THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP MAINTAIN ALL SAFETY DECALS Table of Contents Safety Instructions 1 Limited Warranty 2 Preinstalla...

Page 2: ...IAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESS...

Page 3: ...by wiring the unit to a ground metal clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means 6 Hazardous Pressure Install pressur...

Page 4: ...and in accordance with local and state codes PIPING 1 Old or badly scaled pipe should not be used because dislodged flakes of scale can cause stoppage of the ejector nozzle and malfunction the entire...

Page 5: ...tion 1 Ball Valve plastic 2 3 4 in x 1 4 in bushing steel 3 Pressure Gauge 4 Pump stand for tank 5 Well adapter for single pipe packer installations straight and right angle shown NOTE For a successfu...

Page 6: ...e Pipe System Where water level is greater than 25 feet and inside diameter of well is 4 or larger 1 Attach the foot valve to the ejector using a galvanized steel or plastic nipple Add enough 1 in pre...

Page 7: ...d check for leaks by pouring water into the suction pipe 4 Attach well adapter to suction pipe lower over casing top and tighten adapter flange 5 If no leaks are found proceed to WELL TO PUMP CONNECTI...

Page 8: ...ll with additional pipe and fittings as needed Fig 5 Shallow Well Application Only CAUTION Dry fit entire assembly to ensure proper fit before gluing or taping parts Follow all proper gluing procedure...

Page 9: ...7 5 Glue Deep Well Application Only 1 To begin the connection to the pressure tank loosely assemble flow control body to pump head Using Teflon tape position the discharge outlet of the control body f...

Page 10: ...on this page or step by step instructions on page 11 Your pump motor has a built in thermal overload that protects the motor against burnout from overload of low voltage high voltage and other causes...

Page 11: ...y through the strain relief and tighten both screws on the strain relief Do not crush wire Fig 7 8 Connect the two wires from the power supply to the two outside terminals on the pressure switch Fig 8...

Page 12: ...ming voltage matches the pump wiring voltage See wiring guide in the instructions NOTE Watch for leaks or a milky color in the discharged water which indicates an air leak Make sure foot valve and or...

Page 13: ...the pump is being used for shallow well applications the flow control screw should be set in the full open position IMPORTANT If the pump fails to prime within five minutes Turn power off at the break...

Page 14: ...of liquid soap to the inside diameter of the rubber drive ring 7 Replace the impeller and diffuser removed in Steps 2 3 8 Reassemble the pump body to the motor and mounting bracket MOTOR REPLACEMENT...

Page 15: ...ng Ring Square Cut Seal Rotary w Spring Impeller Diffuser Rubber Diffuser Control Assembly Control Body Flow Control Screw Pump Body Plug 1 4 NPT Pressure Switch Cap Screws 3 8 x 3 4 Base Lead Wire 1...

Page 16: ...pany 2 Reprime if necessary 3 Rearrange piping to eliminate air lock 4 Replace undersized piping or install pump with higher capacity 5 Tighten all fittings and replace control if necessary 6 Make sur...