WELL TO PUMP CONNECTION (SUCTION PIPE)
1. Attach ejector to face of pump with two (2) bolts and gasket provided. Venturi tube on
the ejector inserts into the top tapping of the face of the pump (Fig. 1).
2. Make the connection to your well. Wrap all threaded fittings with pipe tape 5 times and
then apply a pipe paste (pipe dope) to ensure an air tight connection (Fig. 2).
3. The use of a union (optional) will assist with easy connection and disconnect (Fig. 3).
4a. NOTE: For drilled (cased) wells, a foot valve is required in the well at the end of the pipe
to maintain prime (Fig 4a).
4b. For driven wells, a check valve is required at the top of the well to maintain prime. Flow
arrow must point toward pump (Fig. 4b).
5. Finish the connection to your well with additional pipe and fittings as needed (Fig. 5).
Shallow Well Application Only
CAUTION:
Dry-fit entire assembly to ensure proper fit before gluing or taping parts.
Follow all proper gluing procedures as specified by the glue manufacturer. Always glue in a
vertical direction whenever possible to prevent glue from dripping inside pipe or fittings
Use pipe tape and pipe paste compound on all male threads. Tighten with wrench to a snug
fit and add another 1/4 turn to ensure proper seal.
IL1324
Priming Port
Venturi Tube
Ejector
1
IL1346
2
Glue
3
IL1392
Glue
IL1394
5
IL1396
2
IL1395
1
Tape
1. Make the connection to your well. Wrap all threaded fittings with pipe tape 5 times and then apply a pipe paste (pipe dope) to ensure an air
tight connection (Fig. 1).
2. Finish the connection to your well with additional pipe and fittings as needed
(Fig. 2).
Deep Well Application Only
IL1324
IL1346
IL1392
IL1394
IL1395
IL1396
4a
4b
IL1475
Pump
Flow Arrow
IL1392
Flow Arrow
Pump
IL1187