background image

6

5

zogics.com

Problem

Fan is not running.

Machine is running, 
but not spraying.

Intermittent spraying 
or small spray.

Machine is making 
abnormal sounds.

Poor atomization, 
spray nozzle dripping.

Sprayer temperature is 
too high.

Reasons

1. Power cord is loose, poor 
contact, or power copper core is 
broken.
2. Power switch fault.
3. Motor fault.
4. Motor carbon brush is rusted.

1. Chemical tube or valve is 
blocked.
2. Chemical tube or tank tube is 
folded.
3. Chemical tube fell off.
4. Air inlet is blocked.

1. Chemical tube is blocked.
2. Chemical tube is folded.
3. Chemical tube is damaged.
4. Chemical tube fell off.

1. The air inlet is blocked.
2. Motor bearing is damaged or 
carbon brush ran out.

1. Adjusting nut turned too much.
2. Air inlet is blocked.

1. Sprayer has been used 
continuously for too long.
2. Supply voltage does not 
match.
3. Air inlet or outlet is blocked.
4. Motor is worn out.

Solution

1. Check power plug, socket, or 
power cord.
2. Check/replace power switch.
3. Check/repair motor.
4. Check/replace motor brush.

1. Clean or replace.
2. Check chemical tube and 
unfold if folded.
3. Reset chemical tube.
4. Clean & clear air inlet.

1. Clean chemical tube.
2. Unfold chemical tube.
3. Replace chemical tube.
4. Reset chemical tube.

1. Clean & clear air inlet.
2. Repair or replace motor.

1. Turn adjusting nut so it’s not 
opened as much.
2. Clean & clear air inlet.

1. Stop usage for awhile.
2. Select matching voltage.
3. Clean & clear
4. Repair or replace motor.