Error solution
Steps:
1.
Access supervisory interface of operation panel, check at CUR interface, the current value when motor accelerate and
scram. (Normally the value is 0.3)
2.
check the motor well or not : check whether it’s short-circuit between the pin4 and the Pin 1,2,3 of motor’s plug by Using
Ω
channel of multimeter, check whether the impedance of U3 ,V2,W1 of three phase motor is the same
3.
Check whether the motor angle correct or not: check monitor DJ interface [to check if the motor angle in the range of 252
±5 ](if the deviation of motor angle is too big, then motor acceleration or scram will cause large current or
speed uncontrolled
phenomena )
4.
check the impedance of pin 1 /
p
in3 of Q3~Q8: around 10K
5.
Check if the grating loose, or if sensors in encoder board rub with each other.
E2
----Software over-current (soft test motor current over Alert value [16A])
interface
Cur & dj
Q3~Q8
【
IGBT
】
pin
Raster
Installation
height
manually rotate the motor to
see whether the grating touch
the sensor chip,
and height is right in the
center position of the sensor
1 2 3
Summary of Contents for WR580
Page 1: ...WR580 PRODUCT MANUAL V1 0 ...
Page 2: ...Application Model Code Hardware Structure Error Solution Catalogue ...
Page 5: ...Composition of the product ...
Page 9: ...Model description motor Motor model serial number ...
Page 21: ...Function Aging mode Press to enter the aging mode Then press to start press again to stop ...
Page 24: ...External interface definition power 1 2 3 4 Ground wire Power Socket definition L N ...
Page 28: ...Main board PCBA appearance ...
Page 29: ...Control box theory diagram ...
Page 60: ...谢 谢 ...