Error solution
•
Troubleshooting steps
•
1
)
Check whether the inlet voltage of control box is stable, if it’s within the
specified range
of
200V-250V
•
2
)
when standby, see what’s the voltage appear in UDC interface, then run the motor to see how
much voltage rise while scram(usually around 410V),
【
the inlet voltage multiplied by 1.41 =
interface voltage
】
•
3
)
if the voltage showed in UDC is wrong, using Isolation transformer with 80V to supply power,
then detect the voltage of control board’s bridge rec anode to - negative terminal: inlet
voltage multiplied by 1.41; C73 ends impedance: 12.5k or so; Two terminal voltage (means U9
foot 3# to foot 4#(safety line): 0.56V or so.
•
4
)
f the voltage showed in UDC is wrong, using Isolation transformer with 80V to supply power,
then see R143 resistance in main control board: 100
Ω
; C77 ends impedance: 3.3m or so; Two
terminal voltage (means U9 foot 1# to foot 4#(safety line): 0.56V or so.
•
【
share the maintenance picture of E3
】
E10
---
Overvoltage when running
(the bus voltage is less than 80v for 10ms when running)