Error Solution
•
Troubleshooting steps
1
)
Check the encoder socket with main control encoder socket interface
(
Whether inside the encoder
dusty
)
2
)
Check the U3—
p
in 2 impedance to pin 3(ground) which on the encoder board: about 1.2M ; ( the standby
voltage : with the grating angle is different switch between 0V with 5.1V); U3—pin 4 impedance to
p
in
3(ground) : around 20K (the standby voltage : 1.2V), U3—
p
in 2 with J1(
p
in 1 ) whether conduction
( remarks : when encoder is connected with the main control ,the above impedance is different )
3
)
Check the U4—pin 2 impedance to pin 3(ground) which on the encoder board: about 1.2M ; ( the standby
voltage : with the grating angle is different switch between 0V with 5.1V);U4—pin 4 impedance to
pin3(ground) : about 20K (the standby voltage : 1.2V),U4—2stitchs with J1(1 pin ) whether conduction
( remarks : when encoder is connected with the main control ,the above impedance is different )
4
)
Check the U5—pin2 impedance to pin 3(ground) which on the encoder board: about 1.2M ; ( the standby
voltage : with the grating angle is different switch between 0V with 5.1V);U5—pin 4 impedance to
3stitchs(ground) : about 20K (the standby voltage : 1.2V),U5—pin 2 with J1(1 pin ) whether conduction
( remarks : when encoder is connected with the main control ,the above impedance is different )
E11
—HALL initialization signal fault ( when the power on HALL_A
HALL_B HALL_C signal in low level)
Summary of Contents for WR580
Page 1: ...WR580 PRODUCT MANUAL V1 0 ...
Page 2: ...Application Model Code Hardware Structure Error Solution Catalogue ...
Page 5: ...Composition of the product ...
Page 9: ...Model description motor Motor model serial number ...
Page 21: ...Function Aging mode Press to enter the aging mode Then press to start press again to stop ...
Page 24: ...External interface definition power 1 2 3 4 Ground wire Power Socket definition L N ...
Page 28: ...Main board PCBA appearance ...
Page 29: ...Control box theory diagram ...
Page 60: ...谢 谢 ...