The Propaq MD unit assists caregivers during cardiopulmonary resuscitation (CPR) by
evaluating the rate and depth of chest compressions and providing feedback to the rescuer.
Real CPR Help
®
requires the use of ZOLL OneStep™ CPR electrodes, OneStep™ Complete
electrodes, or CPR-D-padz
®
. When using these pads, the displayed ECG waveforms can be
adaptively filtered, using the See-Thru CPR
®
feature, to reduce the artifact caused by chest
compressions.
The unit has a large colorful LCD display of numerics and waveform data that provides easy
visibility from across the room and at any angle. ECG, plethysmograph, and respiration
waveform traces can be displayed simultaneously, giving easy access to all patient monitoring
data at once. The display screen is configurable, so you can choose the best visual layout to fit
your monitoring needs. The Propaq MD includes a transcutaneous pacemaker consisting of a
pulse generator and ECG sensing circuitry. Pacing supports both demand and fixed noninvasive
pacing for adult patients and adolescent, child, and infant pediatric patients.
The Propaq MD has a patient data review and collection system that allows you to view, store,
and transfer patient data. The Propaq MD unit contains a printer and USB port, which you can
use to print the data and transfer it to a PC.
The Propaq MD unit can send data through a wireless connection to remote locations. The unit
can send 12-lead report snapshots (including trend data) to a recipient via a ZOLL server. Full
disclosure cases, which also contain trend data, can be automatically retrieved from the Propaq
MD unit using ZOLL RescueNet
®
or ePCR software.
Propaq MD Optional Features
The following features are optional in the Propaq MD unit.
Note:
All features are included in this manual, but only purchased features will be available
on your unit.
Figure 1-1 Propaq MD Optional Features
Optional Feature
12-Lead ECG with Interpretation
SpO
2
(Masimo
®
) with SpCO
®
and SpMet
®
NIBP (with Smartcuf
®
and SureBP
TM
)
EtCO
2
(Oridion
®
Microstream
®
)
Temperature (2 Channels)
Invasive Pressures (3 Channels)
Advanced CPR Help
Pacing
Wireless communications
Summary of Contents for Propaq MD
Page 1: ...Propaq MD Operator s Guide 9650 0806 01 Rev D...
Page 40: ...CHAPTER 1 GENERAL INFORMATION 1 28 www zoll com 9650 0806 01 Rev D...
Page 60: ...CHAPTER 2 PRODUCT OVERVIEW 2 20 www zoll com 9650 0806 01 Rev D...
Page 74: ...CHAPTER 4 TRENDS 4 4 www zoll com 9650 0806 01 Rev D...
Page 84: ...CHAPTER 5 ALARMS 5 10 www zoll com 9650 0806 01 Rev D...
Page 94: ...CHAPTER 6 MONITORING ECG 6 10 www zoll com 9650 0806 01 Rev D...
Page 104: ...Chapter 7 Monitoring Respiration Resp and Heart Rate HR 7 10 www zoll com 9650 0806 01 Rev D...
Page 120: ...CHAPTER 8 MONITORING NON INVASIVE BLOOD PRESSURE NIBP 8 16 www zoll com 9650 0806 01 Rev D...
Page 154: ...CHAPTER 11 MONITORING INVASIVE PRESSURES IBP 11 10 www zoll com 9650 0806 01 Rev D...
Page 160: ...CHAPTER 12 MONITORING TEMPERATURE 12 6 www zoll com 9650 0806 01 Rev D...
Page 186: ...CHAPTER 14 12 LEAD ECG INTERPRETIVE ANALYSIS 14 16 www zoll com 9650 0806 01 Rev D...
Page 212: ...CHAPTER 17 ADVISORY CPR PROTOCOL DEFIBRILLATION 17 6 www zoll com 9650 0806 01 Rev D...
Page 222: ...CHAPTER 18 EXTERNAL PACING 18 10 www zoll com 9650 0806 01 Rev D...
Page 240: ...CHAPTER 21 PATIENT DATA 21 6 www zoll com 9650 0806 01 Rev D...
Page 268: ...CHAPTER 22 COMMUNICATIONS 22 28 www zoll com 9650 0806 01 Rev D...
Page 284: ...CHAPTER 24 MAINTENANCE 24 12 www zoll com 9650 0806 01 Rev D...
Page 326: ...ACCESSORIES B 6 www zoll com 9650 0806 01 Rev D...