C
HAPTER
17
A
DVISORY
/CPR P
ROTOCOL
D
EFIBRILLATION
17–4
www.zoll.com
9650-0806-01 Rev. D
2 Press ANALYZE
WARNING!
Keep patient motionless during ECG analysis. Do not touch the patient during analysis.
Cease all movement via stretcher or vehicle before analyzing the ECG.
Press the
ANALYZE
quick access key to begin the analysis of the patient’s ECG rhythm and to
determine if a shockable rhythm is present.
The
ANALYZING ECG
and
STAND CLEAR
messages alternate at the bottom of the screen
while the patient’s ECG is analyzed. Once the analysis is completed, the unit indicates whether
or not a shock is advised.
Note:
You can terminate the Advisory/CPR Protocol mode and return to Manual mode at any
time by pressing the
Exit
quick access key.
This analysis normally consists of up to three consecutive 3-second ECG rhythm analyses. If at
least two of the three analyses determine that the patient has a shockable rhythm, the unit
automatically prompts the operator to shock the patient at the preconfigured energy level. If
two or more of the three 3-second ECG analyses do not detect a shockable rhythm, the unit
alerts the operator that no shock is advised.
If the first two segments are in agreement with each other, the final shock or no shock rhythm
decision is made and a third segment is not processed.
WARNING!
ECG rhythm analysis does not warn of patient asystole, which is not a shockable
rhythm.
Summary of Contents for Propaq MD
Page 1: ...Propaq MD Operator s Guide 9650 0806 01 Rev D...
Page 40: ...CHAPTER 1 GENERAL INFORMATION 1 28 www zoll com 9650 0806 01 Rev D...
Page 60: ...CHAPTER 2 PRODUCT OVERVIEW 2 20 www zoll com 9650 0806 01 Rev D...
Page 74: ...CHAPTER 4 TRENDS 4 4 www zoll com 9650 0806 01 Rev D...
Page 84: ...CHAPTER 5 ALARMS 5 10 www zoll com 9650 0806 01 Rev D...
Page 94: ...CHAPTER 6 MONITORING ECG 6 10 www zoll com 9650 0806 01 Rev D...
Page 104: ...Chapter 7 Monitoring Respiration Resp and Heart Rate HR 7 10 www zoll com 9650 0806 01 Rev D...
Page 120: ...CHAPTER 8 MONITORING NON INVASIVE BLOOD PRESSURE NIBP 8 16 www zoll com 9650 0806 01 Rev D...
Page 154: ...CHAPTER 11 MONITORING INVASIVE PRESSURES IBP 11 10 www zoll com 9650 0806 01 Rev D...
Page 160: ...CHAPTER 12 MONITORING TEMPERATURE 12 6 www zoll com 9650 0806 01 Rev D...
Page 186: ...CHAPTER 14 12 LEAD ECG INTERPRETIVE ANALYSIS 14 16 www zoll com 9650 0806 01 Rev D...
Page 212: ...CHAPTER 17 ADVISORY CPR PROTOCOL DEFIBRILLATION 17 6 www zoll com 9650 0806 01 Rev D...
Page 222: ...CHAPTER 18 EXTERNAL PACING 18 10 www zoll com 9650 0806 01 Rev D...
Page 240: ...CHAPTER 21 PATIENT DATA 21 6 www zoll com 9650 0806 01 Rev D...
Page 268: ...CHAPTER 22 COMMUNICATIONS 22 28 www zoll com 9650 0806 01 Rev D...
Page 284: ...CHAPTER 24 MAINTENANCE 24 12 www zoll com 9650 0806 01 Rev D...
Page 326: ...ACCESSORIES B 6 www zoll com 9650 0806 01 Rev D...