Page 10
http://www.meyertech.demon.co.uk
MAN-328
MEYERTECH DIVISION
ISSUE 01
To view the current settings for a camera enter the camera number in the camera field. All other
fields on the page will then be updated with the current operating values.
Editable Fields are:
Camera [ ]
Enter a camera number between 01 and 32. 0 = Global
Video [ ]
Toggle between Video PRESENT and ABSENT. This should be used when
video loss is being detected to discount unused video inputs. Telemetry is
also affected by this field.
Camera Text
Allows the user to enter a caption for the current camera of up to 24
characters in length.
Text Position
Toggle camera caption text position TOP, BOTtom or OFF. This option is
applied to both camera and monitor captions as well as time and date text.
Time / Date [ ]
Toggle time and date display TIME, DATE, BOTH or OFF.
Head Type [ ]
This option defines the RS-422 telemetry protocol output. Options available
are:
DomeVu
Must be selected when driving Meyertech telemetry
receivers DVR-xxx.
ZoneVu
Must be selected when driving Meyertech telemetry
receivers ZVR-xxx over RS-422 .
ZV + VICTA
Must be selected when driving Meyertech telemetry
receivers ZVR-xxx over coaxial cable
M.MERCER
Mark Mercer Domes. D250MPT-AF
JVC
JVC Domes. TK-C675E
For further information regarding Meyertech ZoneVu protocols or any
interfacing requirements please contact Meyertech Head Office. Contact
details can be found at the end of this document.
Caption
Camera text on or off.