ZSC-1000 User Manual.doc
Issue 18
Page 26 of 46
M
E
Y
E
R
T
E
C
H
L
I
M
I
T
E
D
Z
S
C
-1
0
0
0
Local switch
When this option is selected the remote switch will be processed locally
The
Trunk group
value will be used to select a local matrix definition (by number) to perform the switch
This option should not be used if the site number (that the trunk connects to) is the local site. In this case the
switch would automatically be assigned to a local matrix.
Default = 0
Output trunks
Output trunks are the video paths from this site to a remote site. For each output trunk, in the range 0 to 127,
the following can be defined.
Note
: The last trunk should be followed by a ‘dummy’ entry with site set to 0. Gaps should not be left in the
trunk tables as any ‘dummy’ or blank entries in the list are treated as the end of the list.
Site
The site that the trunk connects
Default = 0
Output
Matrix output at the local site that feeds the output trunk
Default = 0
Dialup address
If this entry is anything other than 0, then the site controller attempts to connect to the remote site using the
dialup device with this address.
If the value is zero, the unit assumes that the connection is permanent.
Default = 0
Local switch
Not Used. This option should be left at it’s default value.
Default = 0