Site control
Priority
The priority used by all equipment on this site when trying to control remote sites. The priority ranges from 1
to 9.
Default = 1 (lowest)
Timeout
The time period, in seconds, after which exclusive control of a camera is automatically relinquished if it is not
moved by an operator.
This timeout is applied to control from both local and remote operators.
Default = 600
Enables
This section allows a number of miscellaneous features to be enabled.
Modification of any of these values should be done with care.
Uncontrolled Telemetry
If enabled telemetry is forwarded to the cameras without the requirement for control authentication.
Default = Off
No matrix polling
If enabled, the matrix on the ZVM port will not be polled for alarms.
Default = Off
24 hour alarms
If enabled the alarm handling is permanently enabled. An alarm disable command will effect only attached
alarm panels
Default = Off
Disable ZVR Error Protection
If enabled then this will allow increased flexibility on the operation of 3
rd
party equipment attached to the ZVR
port.
Default = Off