Secondary Action
Relay mask
Unused
Post Action
Action
One of the following actions can be performed on the selected camera (No action, Preset, Walk,
Patrol, Random, Relay On, Relay Off)
For preset, home position will be used; for Walk & Patrol number 1 is used.
For Relay On / Off, the relay number of the primary action is used.
Default = No action
Report
Keyboard
The keyboard that this alarm event is reported to. A number of values have special meanings
•
0 : all
•
99 : All workstations (e.g. Fusion)
•
100 : No reporting
•
101 – 127 : Site 1 - 27
Default = 99
Remote Site
Report the alarm to a remote site (specified in global alarm section)
Default = Off
Notes
If no reporting is specified for all events assigned to an alarm, it will not be seen by any operator and
cannot therefore be cancelled. Such alarms will not be placed on the alarm Queue.
An event with no actions or reporting specified can be used to exclude alarms from a global mapping.
When a blank event is assigned to an alarm, any events assigned further down the alarm list will be
ignored.
Contact Alarms
The ZSC-1000 will poll ZoneVu Alarm cards for alarms. The ZSC-1000 can be configured for these alarms to
be either normally open or normally closed.
For each alarm card, in the range 0 to 14
Alarm card NO/NC
Default = Off