background image

MEYERTECH LIMITED  

 

ISSUE 09

 

 

STEP 1 

 Press  the 

MODE

 key until the required option is displayed. With each press the 

display will show - 

 

 ESC TO LOG OFF   

MONITORS 

ENGINEERING 

  

CAMERAS 

 

ZONAL 

SWITCHING 

 

 

STEP 2 

 Press  the 

ENT 

key 

6.5.1 K

EYBOARD 

C

AMERA 

A

CCESS

 

 

From the 

CAMERA 

menu we can enable and disable access to 

VIDEO 

and 

CONTROL 

for any 

system camera. 

The display will show  

 SUPERVISOR 

 KEYBOARD 

SET-UP 

 CAMERA-1 

 LEVEL 

  ESC 

TO 

EXIT 

 VIDEO-ON 

 

STEP 1 

 Press 

the 

MODE

 key to cycle through the camera options 

 

 

VIDEO-ON 

 

 

CONTROL-ON

 

STEP 2 

 

Use the VCR

 REW

 and 

FF

 keys to cycle through the system cameras 

STEP 3 

 Use 

the 

PROG

 key to Enable or Disable the facility 

 

6.5.2 K

EYBOARD 

M

ONITOR 

A

CCESS

 

 

From the 

MONITOR

 menu we can enable and disable access to 

VIDEO

 and 

SALVO

 and also assign 

MONITOR

 numbers associated with this keyboard to specific video outputs on the VIDEO MATRIX for 

any keyboard monitor. 

The display will show  

 SUPERVISOR 

 KEYBOARD 

SET-UP 

 MONITOR-1 

 LEVEL 

  ESC 

TO 

EXIT 

 VIDEO-ON 

STEP 1 

 Press 

the 

MODE

 key to cycle through the monitor options 

 

 

VIDEO -ON 

 

 

SALVO -ON 

 

 

VOP XR -1

 

STEP 2 

 

Use the VCR 

REW

 and

 FF

 keys to cycle through the keyboard monitors 

STEP 3 

 Use 

the 

PROG

 key to Enable or Disable the facility. 

 

 

Page 17

http://www.meyertech.co.uk

 

MAN-007

 

Summary of Contents for ZVK-007

Page 1: ...SECURITY with VISION ZVK 007 Keyboard USERS MANUAL...

Page 2: ...SELECTION 7 3 CLASIK MODE 7 3 1 CLASIK MODE FACILITIES 7 3 2 SELECTING A CAMERA 8 3 3 SELECTING A MONITOR 8 3 4 CAMERA CONTROL 8 3 5 RELEASING CAMERA CONTROL 9 3 6 SALVO SEQUENCE 9 3 7 PLACING A MONI...

Page 3: ...CESS 16 6 5 KEYBOARD SET UP 16 6 5 1 KEYBOARD CAMERA ACCESS 17 6 5 2 KEYBOARD MONITOR ACCESS 17 6 5 3 KEYBOARD ENGINEERING FACILITIES 18 6 5 4 ZONE SETUP 18 6 6 FEATURE ACCESS 19 6 7 ZVR CONFIGURATION...

Page 4: ...orrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH L...

Page 5: ...t the screen of the Network cable is connected to the PSU 0V connection STEP 3 Plug the Mains Cube into a convenient power socket STEP 4 Plug the ZVK 007 into the FCC connector on the Network Node box...

Page 6: ...User Level Access Password allocation and Keyboard Set up has to be carried out from this Level Video Matrix Configuration and Camera Receiver Configuration can also be carried out from this Level To...

Page 7: ...select the Mode required 3 CLASIK MODE 3 1 CLASIK MODE FACILITIES MONITOR SELECTION 1 64 CAMERA SELECTION 0 512 GLOBAL HOME AUX1 WIPE IRIS AUTO LAMP PRESETS HOME 1 16 PATROL ORDERED RANDOM CAMERA CON...

Page 8: ...ent to MONITOR STEP 3 Press the ENT Key INFO The display will then either retain the Monitor entered indicating a valid entry or show MONITOR ERROR or MONITOR DENIED 3 4 CAMERA CONTROL The Camera show...

Page 9: ...PAUSE keys can be used to control the SALVO switching STEP BACK Each time the STEP BACK key is pressed all patterns are stepped back one frame to display the previous camera picture STEP FORWARD Each...

Page 10: ...camera presets to be recalled in the range 1 16 HOME is a special preset facility which has its own dedicated key STEP 1 Press the PRESET key so the display shows PRESET STEP 2 Enter a PRESET number u...

Page 11: ...onal Switching facility is a powerful feature capable of switching eight cameras to eight monitors with a single keystroke Eight ZONES can be configured per system keyboard see section 5 10 providing...

Page 12: ...UX1 WIPE IRIS AUTO LAMP PRESETS HOME 1 16 PATROL ORDERED RANDOM CAMERA CONTROL PAN TILT ZOOM FOCUS IRIS IRIS AUTO MANUAL AUX1 AUX2 LAMP PWI WASH WIPE When the Keyboard is in SITE MODE the display will...

Page 13: ...cedure STEP 1 Press the Trunk Key labeled as ENC Play INFO If the current trunk was denied a is displayed next to the status to indicate that that the operator has manually accepted the trunk selectio...

Page 14: ...PC Camera selections are made via the PC GUI with the last camera selected being automatically assigned to the keyboard for Camera Control 6 SUPERVISOR LEVEL 6 1 SUPERVISOR LEVEL FEATURES The SUPERVIS...

Page 15: ...ow SUPERVISOR PASSWORDS USER LEVEL 1 LEVEL USER 1 SUPERVISOR PASSWORDS USER LEVEL 2 LEVEL USER 2 SUPERVISOR PASSWORDS USER LEVEL 3 LEVEL USER 3 SUPERVISOR PASSWORDS Supervisor Level LEVEL SUPER USER 6...

Page 16: ...ODE key to cycle through each MODE category The display will show each category and current access status for the USER LEVEL selected SUPERVISOR MODE ACCESS USER LEVEL 1 LEVEL CLASIK GRANT ACCESS INFO...

Page 17: ...P 2 Use the VCR REW and FF keys to cycle through the system cameras STEP 3 Use the PROG key to Enable or Disable the facility 6 5 2 KEYBOARD MONITOR ACCESS From the MONITOR menu we can enable and disa...

Page 18: ...ty 6 5 4 ZONE SETUP Zone Set up allows each of the eight Zones available to be configured with monitor and camera numbers Each Zone can be SIZEd independently in the range 2 8 Up to eight Monitor numb...

Page 19: ...UPERVISOR FEATURE ACCESS LEVEL ESC TO EXIT The first thing we have to do is select the USER LEVEL whose FEATURE ACCESS we wish to configure STEP 1 To select the desired USER LEVEL press the MODE key t...

Page 20: ...K MODE STEP 7 8 The operation of the menus varies according to the receiver type ZVR 510 500 STEP 7 Follow the OSD Menus to configure the camera receiver Select fields by pressing the alphanumeric key...

Page 21: ...in CANCEL HOLD Zoom out 6 8 CAMERA CONFIGURATION CAMERA CONFIG allows the supervisor to directly configure a camera through the receiver using the camera s OSD This option works only with camera type...

Page 22: ...he ENT key the display will show SUPERVISOR ZVM CONFIG LEVEL REQUEST ING ACCESS then REQUEST GRANTED STEP 2 Follow the OSD Menus to configure the video matrix Use the DEL key to move between options a...

Page 23: ...TOP MODE To select a particular VCR to control use the Numeric Keypad by selecting a VCR number in the range of 1 to 8 Note that you do not have to press the ENT key after selecting a VCR number Using...

Page 24: ...X MODE log on to the keyboard and press the MODE key until MUX MODE is displayed Press the enter key and the display will show for example MUX MUX 1 OFF MODE CAM OFF To select a particular MUX to cont...

Page 25: ...s Trouble Shooting Guide should be used in the first instance of encountering any problems with the ZVK 007 If problems persist contact MEYERTECH on the Technical Help line numbers given on page 30 Sy...

Page 26: ...ns All Conforms to the following Product Specifications EN55022 CLASS B EN50093 EN60950 Amendments 1 2 3 1992 Supplementary Information MEYERTECH declare under our sole responsibility that the product...

Page 27: ...nties of merchantability or fitness or otherwise Items manufactured by any supplier other than Meyertech Limited shall bear only the warranty made by the manufacturer of that product and Meyertech Lim...

Page 28: ...UMENT HISTORY ZVK 007 Keyboard Users Manual MAN 007 ISSUE DATE CHANGE RECORD 06 7 October 1997 First Issue in new format 07 18 July 2001 Re issued for Meyertech Limited 08 20 June 2002 Addition of ZVR...

Page 29: ...MEYERTECH LIMITED ISSUE 09 NOTES Page 29 http www meyertech co uk MAN 007...

Page 30: ...e Block One Southlink Business Park Oldham England OL4 1DE Sales Support 44 0 161 628 8406 44 0 161 628 9811 Email sales meyertech co uk Technical Support 44 0 1724 278 833 Email technical meyertech c...

Reviews: