background image

ZOOX AQUARIUM LTD.

Email: info@zooxaquarium.com

Web:http://www.zooxaquarium.com

180402

Summary of Contents for 10000

Page 1: ...User Manual Professional DC Pump 3000 5500 8000 10000 15000 20000 Ultimate Aquarium DC Pump ...

Page 2: ... running in this situation Attention Warning Danger That is mean it may cause property damge or even damage to people Classification of Warning FORBID FORCE UNPLUG THE POWER Meaning of Marks WARNING HANDLING OF POWER PLUG POWER CORD SOCKET FORBID The power supply is AC 100V and the outlet with a rating of 15A or more need to be used alone Use of an AC outlet other than 100V or using an outlet with ...

Page 3: ... indoors below 35 C Do not install in places where the power cord or ballast may get wet It may cause electric shock and leakage Be careful when carrying or installing this product in order to prevent damagefrom product Do not use or placed at outdoors It may cause overheat explosion etc Do not install this product near to children since there is an danger to children WHILE OPERATION In case of ab...

Page 4: ...drop in water level Be careful that do not let sand and foreign matter being sucked into the main unit This can cause serious damage The warranty is not covered in this case Do not use with corrosive or abrasive liquids When holding the pump do not lift the pump by the cord Perform regular cleaning to prevent lime algae calcium and moss from adhering Be sure to turn off the power before connecting ...

Page 5: ...bove O Ring Big O Ring Small Make sure that the pump does not run idle due to a drop in the water level at the pump installation location or water absorption location Since it may cause a pump failure or serious accident The warranty is not cover in this case Install the adapter and controller in a place without heat or humidity Attention Drain hose connector Water intake parts Remove the main uni...

Page 6: ...ontroller Drip loop is mean that the part of the cord is below the location of the outlet as it can prevent water from running down the cord and coming into connect with the outle 4 Connect the power cord to the adapter 5 Make sure that the main unit is underwater and that the inside of the main unit is filled with water before connecting the plug to the outlet Before connecting make sure that the ...

Page 7: ...valve in the middle of piping be sure to provide a bypass point Precautions for Piping Excessive drainage resistance results in reduced flow abnormal pump noise and malfunction Please observe the following precautions Do not use a right angle elbow pipe at the end of the water intake pipe or the dra If necessary use a pipe with a smooth angle ...

Page 8: ...rate by increases the RPM rotational speed as well as decreasing it In addition when resistance is applied to the drainage the RPM rotational speed increases to maintain the set flow rate 1 If you touch the High button while OFF is displayed the pump will Starts running 2 Use the High button and Low button to adjust the flow rate to match the tank Touch the High button to increase the number of rota...

Page 9: ...aintenance cleaning to remove dirt and calcium components regularly at least once a month Also remove dust and dirt from the power cord connection and the outlet 1 Use a hexagon wrench not included so please prepare separately Remove the fixing bolt B At this time be careful not to lose the fixing nut C 2 Remove the pump cover A from the pump core F 3 Remove the impeller D from the pump core F A B C...

Page 10: ...ngs are treated as consumables and are not covered by the warranty We recommend that you apply silicone grease sold separately 4 Use a soft bristle toothbrush to remove any dirt from each part 5 Check the impeller if there any damage 6 Check the O ring if there any damage 7 Reassemble the pump in the reverse order of steps 1 3 and install it in the original place 8 Turn on the power and check for ...

Page 11: ...pter If the problem still exists contact your dealer or us Er04 Water supply drainage pressure Abnormal Check that there is no resistance to water absorption or drainage If necessary review the piping according to Precautions of Piping on page 4 Foreign matter contamination Dirt Disassemble it and clean the pump Er05 Abnormal current Check that if it is connected to the genuine dedicated adapter I...

Page 12: ...ZOOX AQUARIUM LTD Email info zooxaquarium com Web http www zooxaquarium com 180402 ...

Reviews: