background image

 

Hazardous Voltage

 

Earth

 

Double Insulated

 

Low Battery

 

Risk of Danger. Check the User Manual.

A. Introduction

ZT100 is a battery-powered, auto-ranging digital multimeter with a 4000 counts, 

LCD display and backlight. It can be used to measure AC/DC voltage, AC/DC current, 

resistance, capacitance, frequency, duty cycle, diode, and continuity.
B. Safety Information

To avoid possible electrical shock, fire, or personal injury, please read all safety 

information before you use the product.

(1) Do 

NOT 

exceed the “

maximum value

” indicated in the Specification.

(2) Examine the connection of the test leads and the insulation of the product 

before measuring voltage higher than 36V DC or 25V AC.

(3) Disconnect the test leads from the circuit before changing the mode

(4) Misuse of mode or range can lead to hazards, be cautious. “OL” will be shown 

on the display when the input is out of range.

(5) Safety symbols:

C. Specifications

- 1 -

- 3 -

- 4 -

- 2 -

Electrical Specifications

Function

Range

Resolution

Accuracy

MAX.Value

Other

DC Voltage

400.0mV 0.1mV

±

(0.5%+4)

1000V

4.000V

0.001V

40.00V

0.01V

400.0V

0.1V

±

(0.8%+4)

1000V

1V

AC Voltage

400.0mV 0.1mV

±(1.2%+4)

750V

40Hz-400Hz

4.000V

0.001V

40.00V

0.01V

400.0V

0.1V

750V

1V

±

(1.5%+4)

DC Current  

(A)

4.000A

0.001A

±

(1.5%+4)

10A

10.00A

0.01A

DC Current  

(mA)

40.00mA 0.01mA

400mA

400.0mA 0.1mA

AC Current  

(A)

4.000A

0.001A

±

(2.0%+4)

10A

40Hz-400Hz

10.00A

0.01A

AC Current  

(mA)

40.00mA 0.01mA

400mA

400.0mA 0.1mA

Function

Range

Resolution

Accuracy

MAX.Value

Other

Resistance

400.0Ω

0.1Ω

±

(0.8%+4)

40MΩ

4.000kΩ

0.001kΩ

40.00kΩ

0.01kΩ

400.0kΩ

0.1kΩ

4.000MΩ

0.001MΩ

40.00MΩ

0.01MΩ

±

(2.0%+4)

Capacitance

4.000nF

0.001nF

±

(5.0%+20)

200μF

40.00nF

0.01nF

±(3.5%+4)

400.0nF

0.1nF

4.000μF

0.001μF

40.00μF

0.01μF

200.0μF

0.1μF

Frequency

99.99Hz

0.01Hz

±

(0.1%+2)

9.999MHz

999.9Hz

0.1Hz

9.999kHz

0.001kHz

99.99kHz

0.01kHz

999.9kHz

0.1kHz

9.999MHz

0.001MHz

Duty Cycle 1%~99%

0.1%

±

(0.1%+2)

Diode

Continuity

1

2a

2b

3

4

5

6

ZT100 Digital Multimeter 

User Manual

General Specifications

Display

LCD

4000 counts

Ranging

Auto

Material

ABS

Update Rate

3 times/second

Ture RMS

×

Data Hold

Backlight

Low Battery Indication

Auto Power Off

Mechanical Specifications

Dimension

130*65*32mm

Weight

130g

Battery Type

1.5V AAA Battery * 2

Warranty

One years

Environmental Specifications

Operating

Temperature

0~40

Humidity

75%

Storage

Temperature

-20~60

Humidity

80%

Safety Specifications

EN 61010-1: 2010; EN 61326-1: 2013; FCC Part 15 Sbupart: 2016

Standard Accessories

Battery * 2pcs; Test Lead * 1 pair; English User Manual; Gift Box

D. Instruction

 (1) Front Panel

see the picture on the right

1. LCD display

2. Bottons

2a. HOLD: To hold the current reading, press this 

button and you will see “HOLD” on the display; 

press again to cancel. To turn on the backlight, 

press this botton for more than 2 seconds; 

long-press again to turn off.

2b. SELECT: To toggle between AC/DC, 

Resistance/Diode/Continuity/Capacitance, or 

Frequency/Duty Cycle, press this botton.

3. Rotary Switch: To change mode or range

    (from OFF, clockwise)

3a. OFF

3b. AC Voltage

3c. DC Voltage 

3d. Resistance/Diode/Continuity/Capacitance

3e. Frequency/Duty Cycle  

3f. AC/DC Current (A) (Current-A Mode)

3g. AC/DC Current (mA) (Current-mA Mode)

3h. OFF

4. VΩHz: Input terminal for voltage, resistance, 

                capacitance, frequency, current (mA),  

                continuity, diode, and duty cycle 

                measurements.

5. COM: Common terminal for all measurements.

6. 10A: Input terminal for current (A) measurements.

(2) Measure AC/DC Current

1. Connect the black test lead to the COM Terminal and connect the red test lead 

    to the VΩHz Terminal or the 10A Terminal (choose based on the value of 

    current) ;

2. Turn the rotary switch to the Current-A Mode or the Current-mA Mode;

3. Press SELECT to toggle between AC/DC;

4. Break the circuit path to be measured. Then connect the test leads across the 

     break and apply power;

5. Read the measured current on the display.

*Caution:

a. Do not measure current that exceeds the MAX Value as indicated in the  

  

  

 Specifications;

b. Use the 10A Terminal and the Current-A Mode when you are measureing an 

     unknown current. Then switch to the VΩHz Termianl and the Current-mA Mode if 

     necessary.

Do not input voltage exceeds 36V DC or 25V AC when you are at the 

setting of measuring current.

Reviews: