14-1
14 Power-on/Power-off
Summary:
z
Power-on/Power-off of the PWS (AC/DC) of the BTSB
z
Power-on/Power-off the BDS shelf
z
Power-on/Power-off the RFS shelf
14.1 Checking before Power-on
Check the following power switches:
1
The upper level switch of the AC power
2. The input AC power switch of the system
3. The DC power switch of the BDS shelf
4. The DC power switch of the RFS shelf
5. The battery loop switch that is in the rupturing state
14.1.1 Checking the External Connections of the Rack
1. Check the AC power connection: Examine carefully whether the power cable
connected to the AC power cable terminal of the PWS shelf at the cabinet top is
correctly connected. (Note: This power supply can be AC 220V 3-wire input
with voltage ranging 150V
∼
285V, or AC tri-phrase five-wire input with voltage
ranging 150V
∼
285V and line voltage 270V
∼
490V.) Do not reversely connect
the live wire and the null wire and be sure to fasten the screws.
2. Check the DC power connection: Examine carefully whether the terminal block
is correctly connected to the DC battery of the PWS shelf. Be sure that the
polarity is not reversely connected, the voltage is in the range of -40V
∼
-57V,
and the screws are fastened.
3. Make sure that E1 cables are correctly connected without insecure connections.
Summary of Contents for ZXC10 BTSB I1
Page 4: ......
Page 16: ......
Page 22: ... ii Table C 2 1 BTSB Board Indicators C 2 ...
Page 76: ......
Page 91: ...Chapter 7 Cable Installation in Cabinet 7 15 Fig 7 3 5 RF Cable Interface in RFS ...
Page 96: ......
Page 106: ......
Page 114: ......
Page 157: ...Chapter 12 Board Installation 12 11 Fig 12 5 1 Positions of Boards ...
Page 158: ......
Page 174: ......
Page 180: ......