ZXC10 BTSB (V1.0) cdma2000 Base Transceiver Station Installation Manual
B-2
B.3 Inputting feeder parameters
1. Press
<DIST>.
2. Press
<MORE>.
3. Press <LOSS> to enter the feeder loss per meter (dB), which varies with
providers and models. Then press <ENTER> for confirmation.
4. Press <PROP V> to enter the relative transmission rate, which varies with
providers and models. Then press <ENTER> for confirmation.
5. Press <MAIN> to return to the main menu.
B.4 Installing the tester
Connect one end of the self-contained extension cable to the RFE jumper connector
inside the rack and the other terminal to the Refl interface of the meter.
If there is an active device like a tower top amplifier or a trunk amplifier in the feeder
measuring, jumpers shall be used to dodge it.
B.5 Measuring SWR
1. Press<OPT>.
2. Press <B1> to choose [MODE].
3. Press <Up> or <Down> to select [SWR] and press <ENTER> for confirmation.
4. Press<MAIN> to return to the main menu.
5. Input a proper frequency range if necessary.
6. Check the meter if necessary.
7. Press<MAIN> to return to the main menu.
8. Press<RUN> to begin the measure.
9. Press <AUTOSCALE> to adjust the Y-coordinate.
10. View the SWR values of the frequency points within this frequency band, as
shown in Fig. B.5-1.
Summary of Contents for ZXC10 BTSB I1
Page 4: ......
Page 16: ......
Page 22: ... ii Table C 2 1 BTSB Board Indicators C 2 ...
Page 76: ......
Page 91: ...Chapter 7 Cable Installation in Cabinet 7 15 Fig 7 3 5 RF Cable Interface in RFS ...
Page 96: ......
Page 106: ......
Page 114: ......
Page 157: ...Chapter 12 Board Installation 12 11 Fig 12 5 1 Positions of Boards ...
Page 158: ......
Page 174: ......
Page 180: ......