12-1
12 Power-on and Power-off
Summary
Describing the power-on check items
Describing the procedures to power on/off a
micro-BTS/remote station
12.1 Checking Components in the Cabinet before Power-on
Open the cabinet to check if the modules are installed firmly and the cables are
connected reliably.
Insert the OIM and the CSM5000 into the cabinet.
Set the PATH ID by setting the DIP switch on the BDM based on the T1 cable
connections with the CDSU of the BSC. See Fig. 12.1-1 for the setting of the DIP
switch.
PATH_ID1
2
PATH_ID2
PATH_ID3
PATH_ID0
4
ON
OFF
When PATH_ID=1, the DIP switch is set as:
When PATH_ID=5, the DIP switch is set as:
ON
OFF
ON
OFF
3
1
Fig. 12.1-1 Setting of S1