Chapter
6
Installation
of Grounding System
6-3
In actual installation, first determine the position for the copper busbar based on the
engineering design drawing, and then install the busbar on the wall with expansion
bolts. See Fig. 6.2-1 for the appearance of the grounding copper busbar.
Fig. 6.2-1 Appearance of a Grounding Copper Busbar
6.2.2 Installing the Grounding System of Micro-BTS
The cabinets of ultra-wide coverage micro-BTS/remote stations are equipped with
PGND terminals, as shown in Fig. 6.2-2. The PGND terminal is connected to the
indoor grounding copper busbar via the 16mm
2
yellow or olivine conducting wire. If
the equipment is installed outdoors, the PGND terminal is connected with the
grounding cable from the tower or from the top of the building in the crimping
connection mode.