ZXG10-BTS (V2.9) Technical Manual
20
Confidential and Proprietary Information of ZTE CORPORATION
The weight bearing capacity of the equipment room ground should be
1,200 kg/m
2.
Power Supply of Equipment
Voltage
Nominal working voltage: -48 VDC
Range: -57 VDC ~ -40 VDC
Power Consumption
The maximal power consumption of each module is as follows:
TRM: 160 W
TRM: 175 W
CMM: 16 W
Fan: 60 W
CDU or RDU: 5 W
The power consumption of the integrated equipment in full configuration is
less than 2,200 W.
Heat in the rack is from the TRM and AEM in the carrier plug-in shelf.
The heat consumption distribution of each module:
TRM: 120 W
ETRM: 135 W
AEM: 45 W
CMM (two): 20 W
Fan and other parts: 30 W
Under full configuration:
Without ETRM, the heat consumption of each carrier shelf, 600 W;
integrated equipment, less than 2,200 W
With ETRM, the heat consumption of each carrier shelf (fan included),
600 W; integrated equipment, less than 2,350 W