Chapter 2 - Technical Indices
Confidential and Proprietary Information of ZTE CORPORATION 21
Environmental Conditions
Temperature and Humidity Requirements
Working temperature: -5 ºC ~
4
5 ºC
Relative humidity: 10% ~ 90 %, no condensation
Grounding Requirements
The case of the rack should be grounded well, with the grounding
resistance less than 5 ohm.
Atmospheric Pressure Requirements
1.08 × 10
5
pa ~ 5.1 × 10
4
pa (-500 mm ~ +500 mm)
Lighting
Direct sunshine should be avoided to prevent the circuit boards and other
components from aging and deforming. The average illumination should be
300x ~ 450lx and no glare should exist.
Air Pollution
Erosive gases, smog and smoking are prohibited in the equipment room.
Interface Indices
Abis Interface Indices
The Abis interface adopts the standard E1 interface.
The performance of the Abis interface meets the requirements specified by
ITU-T G.703 and ITU-T G.704. Details are as follows:
1. Basic requirements
i. Nominal bit rate: 2,048 Kbit/s
ii. Bit rate tolerance: ± 50 × 10
-6
iii. Signal code pattern: HDB3
2. Electrical features
i. Pulse shape: rectangular
ii. Nominal peak voltage of pulse (mark):
2.37 V (75 ohm, a pair of coaxial cables).