Chapter 2 - Technical Indices
Confidential and Proprietary Information of ZTE CORPORATION 25
Clock Indices
It provides a two-level clock, whose indices are as follows:
Clock accuracy: ±1.0×10
-9
Pull in range: ±1.0×10
-9
Maximum frequency bias: 1 × 10
-9
/day
Initial maximum frequency bias: 1×10
-7
Reliability Indices
MTBF (Mean Time Between Failure) (hour): 6.3 ~ 10
4
hours
Mean Time To Repairs (MTTR): 0.57 hours
Availability ratio A (%): 99.9991%
Annual average interruption time of the system (hour): 0.080 hours
The product successfully passed the CE certification. The personal safety,
electromagnetic security, EMC and guarantee of the wireless frequency
spectrum comply with international standards.