ZXR10 8900E series Core Switch Product Description
ZTE Confidential Proprietary
© 2013 ZTE CORPORATION. All rights reserved.
79
−
10G Ethernet service card
−
40G Ethernet service card
Power supply
8900E uses intelligent power supply unit. Main control system can monitor the power
supply by RS485 interface to implement its intelligent monitoring of temperature,
over/low-voltage, power-down alarm, and traffic limit.
Intelligent fan
8900E system uses intelligent fan to satisfy the functional requirements of fan speed
adjusting, fan off alarm, fan speed alarm, and fan card temperature detection. It can also
adjust the speed for fan at each slot based on their temperature to save energy.
4.2.2
Working Principles of Hardware System
ZXR10 8912E/8908E/8905E core switch system adopts a distributed architecture which
is composed of forwarding, control and monitoring planes. Forwarding plane implements
wire-speed switching by two-layer hardware switching. Layer 1 switching is implemented
between ports of line cards by local ASIC chip, which is usually called Packet Processor
(abbreviated as PP). Layer 2 switching is implemented between line cards by the
switching matrix on the main control card. It can connect all PP to constitute a
large-capacity switch system. On the control plane, each line card has an independent
CPU to conduct local packet forwarding and protocol processing. It can communicate
with main control card CPU by high-speed channel. CPU implements route calculation,
management and control. The main monitoring node on main control card,
sub-monitoring node on line card and monitoring bus connecting all monitoring nodes
constitute a monitoring plane to realize the monitoring of the equipment and state of the
whole system. The system diagram is shown in Figure 4-11.
Summary of Contents for ZXR10 8900E series
Page 1: ...Operator Logo ZXR10 8900E series Core Switch Product Description ...
Page 2: ......
Page 10: ......