3.4 Power Indices
Local power voltage range: 85 V AC to 264 V AC.
The typical power consumption is 33 W.
3.5 Temperature and Humidity
Temperature: -20
℃
to +45
℃
. The change frequency must be less than 0.5
℃
/min.
Relative humidity: 5% to 95%
3.6 Environmental Classes
l
Grade Of Protection: IP30.
l
Grounding Requirements: Joint grounding resistance less 1 Ω; BTS grounding
resistance less 5 Ω.
l
Noise: Noise of working environment: less 65 dBA.
3.7 RF Indices
RF indices of the ZXSDR BS8802 C100 comply with
3GPP2 C.S0010-C, Recommended
Minimum Performance Standards for cdma2000 Spread Spectrum Base Station
and
3GPP2 C.S0032-A, Recommended Minimum Performance Standards for CDMA2000
High Rate Packet Data Access Network
.
illustrates the 800 MHz transmitter indices.
Table 3-2 800 MHz Transmitter Indices
Name
Index
Operating band
800 MHz (Band Class 0)
Transmitter output frequency tolerance
± 0.01 ppm
Occupied channel bandwidth
1.23 MHz (Band Class 0)
Output power at the Top of Cabinet
(TOC)
600 mW
Total transmit power
The total transmit power is 2 dB and -4 dB of the
manufacturer’s rated power.