background image

11

Seite

Seite

Page

Enter

010- CERAMAY

450C 

Edit “  140 CRISTALLISATION “

Program type

Special

-Start temp

450C

-Pre dry

Yes

-Pre dry time

2:00

-Closing time

4:00

-Soak temp

450C

-Soak time

0:30

-Heat rate 1

50C

-Final temp 1

900C

-Hold time 1

1:00

-Heat rate 2

45C

-Final temp 2

920C

-Hold time 2

0:25

-Open temp

920C

-Opening time

1:00

-Vacuum

Yes

-Release  vacuum Heat up

-Vacuum End

820C

Esc

Start temperature

Temperature in the 

firing chamber at which the program starts.

Pre-dry

Selecting “YES” activates the special pre-

drying program.

Pre-dry time

Enter a time. In this section, the lift

identifies a predefined position for the entire
time, depending on the heat radiated by the
firing chamber. The object can thus be pre-dried
at a constant temperature.

Closing time

Time in which the lift moves in 10

increments into the firing chamber.

Soak temperature

At this temperature, the object

remains in the closed firing chamber in order to
achieve an even temperature distribution.

Soak time

States the retention period of the object

in the firing chamber before evacuation and the
temperature increase.

Heat rate 1

Temperature increase per minute in

order to reach the final temperature 1.

Final temperature 1

Temperature 1 at which the

ceramic is sintered.

Hold time 1

Period for which the ceramic is main-

tained at the final temperature 1.

Heat rate 2

Temperature increase per minute in

order to reach the final temperature 2.

Final temperature 2

Temperature 2 at which the

ceramic is sintered.

Hold time 2

Period for which the ceramic is main-

tained at the final temperature 2.

Open temperature

Temperature at which the devi-

ce opens the firing chamber.

Opening time

Decent time of the lift from the

chamber to the fully open position.

Vacuum

Selecting “YES” activates the vacuum

parameter (firing under vacuum).

Vacuum release

(

=Selection)

During the heating up stage 

“Release Vacuum Heat up”

During the hold time at final temperature 

“Release Vacuum Hold time”

During the cooling stage 

“Release Vacuum Cooling”

Vacuum end

Display shows temperature at which

the vacuum is released.

Edit done?

Saving of the program.

Program types - 3:  

Special Program  

This firing program is recommended for processing ceramic materials,

which require two holding times under vacuum and/or two different heat rates (specially for crystallization programs
for IPS e.max e.max

®

CAD)

1 Operation 

Summary of Contents for VARIO 200

Page 1: ...www zubler de VARIO 2 20 00 0 Operating instructions 01 2014 en Ceramic Furnace...

Page 2: ......

Page 3: ...ust display 1 3 9 Audio Beeps 1 3 10 Set preview mode 1 3 11 Initial oven setup 1 4 Run warm up program 1 5 Start night mode 1 5 1 Stand by temperature 2 Service Page 18 2 1 Fuse 2 2 Filter element fo...

Page 4: ...ng management for all dental ceramics available on the market The use of materials of the highest quality increases the lifetime of the furnace enabling you to reproduce optimal results over many year...

Page 5: ...during which the pump draws vacuum for 2 minutes After which a leakage test starts for another 2 minutes to check the seals of the firing chamber 10 Finally there appears the prompt Set Vacuum level...

Page 6: ...rnace chamber or table slide bar Never use hard or sharp objects to operate the touch screen The oven must always have a firing brick on the lift table During operation never place your hand between t...

Page 7: ...program To switch to another program group touch the red Esc key To switch to a different program group touch the red ESC button Use the yellow Next key the key or the dialer select the desired progr...

Page 8: ...irm by pressing the green Enter key This will advance you to the program editing screen Use the key or the dialer to select the desi red program type and confirm with the green Enter key The firing pa...

Page 9: ...ak time States the retention period of the object in the firing chamber before evacuation and the temperature increase Heat rate Temperature increase per minute Final temperature Temperature at which...

Page 10: ...onstant temperature Closing time Time in which the lift moves in 10 increments into the firing chamber Heat rate Temperature increase per minute in order to reach the final temperature Final temperatu...

Page 11: ...ature increase Heat rate 1 Temperature increase per minute in order to reach the final temperature 1 Final temperature 1 Temperature 1 at which the ceramic is sintered Hold time 1 Period for which the...

Page 12: ...g chamber before evacuation and the temperature increase Heat rate Temperature increase per minute Final temp Temperature at which the ceramic is sintered Hold time Period for which the ceramic is mai...

Page 13: ...e brand to which the program is to be moved using the keys or the dialer and press the green Enter key Select the place to which the program is to be moved using the keys or the dialer and press the g...

Page 14: ...the green Enter key to exit the Brand page New Change mode or by pressing the red Esc button you return to the Edit Programs screen 1 2 7 Erase brand Use the dialer or the keys to select the brand na...

Page 15: ...the calibration within certain temperature ranges This feature changes all the final temperatures of programs in the respecti ve temperature range below above 800 C 1472 F 1 3 4 Vacuum pump This secti...

Page 16: ...rsion Displays the software version currently installed Update software Requires the entry of a password We will provide the password and instructions with software updates Service tests Vacuum test d...

Page 17: ...by pres sing abort 1 5 1 Stand by temperature To save energy and prevent impujriteis or con densation inside the furnace we advise you to keep the firing chamber closed when it is not being used Shoul...

Page 18: ...recommend you replace this filter element at least every 3 years 2 3 Run purge program From the main menu select the following options using the keys or the dialer and confirm by pressing the green En...

Page 19: ...he device will remain in this state for 30 minutes At the end of this time the device will enter stand by mode and close automatically after the defined stand by temperature of 100 C has been reached...

Page 20: ...of a malfunction After any extended period without use as well as high humidity or low temperature it may not be possible to generate a sufficient vacuum initial ly This is normal 3 2 Included 3 1 te...

Page 21: ...r the heating elements or the interior surface of the heating chamber These surfaces may cause severe burns Always keep the chamber closed with the lift in the up position between processes or when th...

Page 22: ...Dispose of fiber waste in sealed containers After handling rinse exposed skin with water before washing gently with soap not detergent Wash work clothing separately Because this product and many simi...

Page 23: ...HANGE THESE VALUES is displayed press the green Enter button and the first Temp Difference will be highlighted indicating it is ready for adjustment Using the dialer or buttons indicate the number of...

Page 24: ...B000xx 02 2014 C Zubler Ger tebau GmbH Buchbrunnenweg 26 D 89081 Ulm Jungingen www zubler de m V200 de 09 2014 technische nderungen vorbehalten en...