19
Seite
Seite
Seite
Seite
Page
2 Service
2.5 Operational Information
The operator using the furnace must close the
lift after completing a firing program
After closing the lift, the unit will remain at the pro-
grammed idle temperature for four hours. If the unit
is not used, it will automatically go into the “stand-
by” mode.
If, at the end of the program, the chamber is not
manually closed, the device will automatically cool
down to the safety temperature of 400°C, indepen-
dent of the idle temperature selected. Once this
temperature has been reached, the device will
remain in this state for 30 minutes.
At the end of this time, the device will enter stand-
by mode and close automatically after the defined
stand-by temperature of 100°C has been reached.
Duplicate program names are not allowed.
Overwriting a program during operation
(see 1.1 Run Programs)
1. Should you find that you have to temporarily
change one or more parameters while a program is
running, you can do this by pressing the yellow
“Edit Prog.” key below the display.
2. In general, you can only change parameters that
have not already been started when you press the
yellow “Edit Prog.” key.
3. The changes you have made are temporary and
apply only to the current firing cycle.
4. Editing can be carried out only once during the
firing cycle.