23 / 61
Identification: MD-AL-GI-00
Rev. 4.0 of 31.01.18 - Application: GID
Manual of 07/06/2019 Rev. 2.1 “User Manual for 1.1K-3K TL”
Figure 14 – Preparing the ground cable (1)
2)
Insert the exposed wires in the OT terminal using a crimp tool, as shown in figure 15.
Note 1
: L3 is the length between the insulation layer of the ground cable and the crimped part. L4 is the
distance between the crimped part and the conductor wires protruding from the crimped part.
Note 2
: The cavity formed after the conductor has been crimp must completely wrap the conductor wires.
The core of the wire must be in close contact with the terminal.
Figure 15 – Preparing the ground cable (2)
3)
Install the crimped OT terminal and flat washer using the M5 screw in the hole located on the
inverter heatsink, as shown in the figure; tighten the screw to a torque of 3 Nm using an Allen key.
Figure 16 – Connecting the ground terminal