30 / 61
Identification: MD-AL-GI-00
Rev. 4.0 of 31.01.18 - Application: GID
Manual of 07/06/2019 Rev. 2.1 “User Manual for 1.1K-3K TL”
Figure 29 – Connecting the AC output cables (3)
4)
Secure the clamping cable gland by turning it clockwise, as shown below; make sure that all the wires
are securely connected
5)
Connect the AC output connector to the output terminal of the inverter; turn the AC connector in a
clockwise direction until the fixing device reaches its intended position, as shown below:
Figure 30 – Connecting the AC output cables (4)
4.5.
Connecting the communication cables
Connecting the communication port
Note: The wiring procedure is the same for the RS485 input, I/O input and CT input. This chapter describes
the steps to be followed for connecting the communication cables.
Communication port
RS485
I/O
CT
Cable cross-section
0.5-1.5 mm
2
0.5-1.5 mm
2
0.5-1.5 mm
2
Outer diameter
2.5~6 mm
2.5~6 mm
2.5~6 mm
Table 3 – Recommended specifications for communication cables
1)
Remove the central waterproof cover of the communication terminal block using a star screwdriver;