59 / 61
Identification: MD-AL-GI-00
Rev. 4.0 of 31.01.18 - Application: GID
Manual of 07/06/2019 Rev. 2.1 “User Manual for 1.1K-3K TL”
8.
Uninstalling
8.1.
Steps for uninstalling the inverter
Disconnect the inverter from the AC grid.
Switch off the DC switch
Wait 5 minutes
Remove the DC connectors
Remove the AC terminals.
Unscrew the fixing bolt of the bracket and remove the inverter from the wall.
8.2.
Packaging
If possible, pack the inverter in its original packaging.
8.3.
Storage
Store the inverter in a dry place where the ambient temperature is between -25 and +60°C.
8.4.
Disposal
At the end of its life, dispose of the inverter and the packaging materials in places that can manage and
recycle electrical equipment safely.
9.
Technical specifications
Technical specifications
1100TL
1600TL
2200TL
2700TL
3000TL
Input (DC)
Typical power of PV system
1200W
1800W
2400W
2900W
3300W
Number of MPPTs / Number of
strings per MPPT
1 / 1
Maximum DC input voltage
450V
500V
Input activation voltage
100V
120V
Rated DC input voltage
360V
MPPT DC voltage range
80V-450V
100V-500V
DC voltage range at full load
110V-450V
165V-450V
170V-500V
200V-500V
Max input DC current
10A
13A
13.5A
15A
Output (AC)
Rated AC output power
1000W
1550W
2100W
2600W
3000W
Maximum AC power
1000
VA
1550VA
2100VA
2600VA
3000VA
Maximum AC current
4.5A
7A
9.5A
11.5A
13A
Rated AC voltage
L/N/PE, 220, 230, 240 V