Minipool
MAIN ERRoRS DISPLAYED oN THE KEYBoARD
FLo:
It indicates the lack of flow when there should be.
It can be caused by a dirty filter, a closed recirculation system
valve or by recirculation pump failure
ER:
It indicates that the maximum temperature of >45°C was
exceeded or the temperature is under <5°C. All loads are
automatically cut-off. The error conditions is automatically
reset if the temperature returns within the normal range.
FLC/Temp.°C:
The flow gauge reads the water flow despite the
pump being off. In normal conditions, it is displayed dur-
ing the filling phase, alternating with the temperature. Or it
indicates a flow gauge fault
HI:
Maximum >42°C temperature exceeded
All loads are cut-off. It may also be caused by an exchanger
solenoid valve failure.
LL:
The pool level capacitive sensor does not read water.
Pool water level too low. The sensor can also be influenced
by residue in the pool or be defective.
ICE:
It indicates that the automatic defrost system has turned on
It automatically turns on when the water temperature drops
below 7°C.
If an error message appears, try to resolve it by following
the instructions. If the problem cannot be resolved, unplug
the minipool from the power supply and contact a Service
Centre authorised by the Manufacturer.