PN series frame version
Malfunctions
Error messages
5-5
110008,001,11-2009, jmu
5
Hint
See chapter "Emergency stop" in the description of the electronics. It is usu
-
ally possible to carry out a software reinitialisation if the external emergency
stop print no. 5 000 458 is not installed.
0801
Emergency stop
<ENT> to reinit
0802
Light-barrier
Check working area
Cause
Lightbarrier interrupted or error detected in the test cycle.
Index
0 : Light barrier interrupted (normal cycle) 1 : Error in light barrier 1 test cycle
2 : Error in light barrier 2 test cycle 3 : Error in light barrier 3 test cycle
Action
If the interruption occurs in the normal cycle, remove the object causing the
interruption, clear the error message and return to online operation if neces
-
sary. If an error occurs, see the "Light barrier" chapter in the description of
the electronics.
Comment
All connected lightbarriers are active if at least one lightbarrier is activated in
the menu. All connected lightbarriers must be activated in the menu to eva
-
luate the corresponding test cycle.
0803
Emergency stop
Turn off plotter!
Cause
Emergency stop initiated during plotter initialisation
Index
0 : In normal cycle 1: In the test cycle
Action
If initiated in a normal cycle, remove the reason for the emergency stop and
switch plotter off and on. If the reason is not clear, possible causes could be
a interrupted emergency loop, a defective master board, a short circuit to a
voltage > 2.5 volts or noise.If initiated in a test cycle a hardware error or
noise caused the message. Possible causes could be a short circuit against
ground or case, or a defective master board.
Hint
See chapter "Emergency stop" in the description of the electronics. Soft
-
ware reinitialisation is not possible.
0901
SPI-Communication
No Link to Slave
Cause
Communication to a certain SPI slave-processor is no longer possible. Con
-
nection interrupted or disturbed, board defective or +5V too low.
Index
Slave-number
Text
Name of the board
Action
Check the connection, 5V (see the "Power supply" chapter), replace
the board or cabling.
Comment
It is possible that the slave displayed is not faulty and that its communication
is being interrupted by a different faulty slave.
Hint
See chapter "SPI" in the description of the electronics.
0902
SPI-Communication
SPI-Slave not found
Cause
This error corresponds to error 0901. The number is 0902 if the problem
already exists when the system starts after power up. See error 0901 for
more information
1001
Head Changed
Turn off plotter!
Cause
Head changed while plotter is on or error in the head recognition connec
-
tions.
Index
False recognition code (decimal number, from MC >= V1.82)
Hint
See chapter "Head recognition code" in the description of the electronics.
Comment
Plotter must be switched off before head exchange
Summary of Contents for L-1200
Page 6: ...PN series frame version 0 4 110002 001 11 2009 jmu 0 ...
Page 14: ...Introduction PN series frame version Publishing details 1 8 110003 001 11 2009 jmu 1 ...
Page 48: ...Safety PN series frame version Disposal 3 26 110005 001 11 2009 jmu 3 ...
Page 123: ...PN series frame version Tools 7 1 100011 003 11 2009 jmu 7 7 Tools ...
Page 124: ...Tools PN series frame version 7 2 100011 003 11 2009 jmu 7 ...
Page 125: ...PN series frame version Tool heads 8 1 110008 001 11 2009 jmu 8 8 Tool heads ...
Page 126: ...Tool heads PN series frame version 8 2 110008 001 11 2009 jmu 8 ...
Page 127: ...PN series frame version Options 9 1 100015 001 11 2009 jmu 9 9 Options ...
Page 128: ...Options PN series frame version 9 2 100015 001 11 2009 jmu 9 ...
Page 129: ...PN series frame version Material feed 10 1 100012 003 11 2009 jmu 10 10 Material feed ...
Page 130: ...Material feed PN series frame version 10 2 100012 003 11 2009 jmu 10 ...
Page 132: ...Additional specifications PN series frame version 11 2 100014 003 11 2009 jmu 11 ...
Page 133: ...PN series frame version Documents 12 1 100017 001 11 2009 jmu 12 12 Documents ...
Page 134: ...Documents PN series frame version 12 2 100017 001 11 2009 jmu 12 ...
Page 142: ...Annex PN series frame version Service and maintenance works 13 8 100013 003 11 2009 jmu 13 ...