PAGE 22
MAJ-14
14. OPTIMAL WORKING SETTINGS
The sprayers from series SN are designed for work in vineyard and orchard. The sprayer can
adapt to various heights and widths of the plantation.
Fan shape
Row width
(m)
Spraying height
max.
(m)
Fan shape with 8 nozzles
20.000 m³/h
min. 2,0 m
2,5 m
2,5 m
2,8 m
max. 3,0 m
3,0 m
Fan shape with 10 nozzles
20.000 m³/h
min. 1,8 m
2,5 m
2,5 m
2,8 m
max. 3,0 m
3,0 m
Set the optimal working position of the nozzles in the plantation with the highest culture; for the
lower cultures just close the upper nozzles.
Help
You need for the settings:
-
measure stick, length: 4 m
-
measure tape 2 m
-
scotch tape for marking
-
a stick for nozzle setting 2 m
Setting the sprayer for the highest threes
-
the minimum spraying height should be 20 cm, measured from the ground, or set
depending on the culture
-
the maximum spraying height should be the three height plus 20 cm
Nozzle settings
•
Divide the spraying heights defined before, with the nozzle number and mark the parts
with the tape on the measure stick.
•
Direct the nozzles to the marked spots:
-
Put the stick for the nozzle setting on the nozzle and on the mark on the
measure stick the turn the nozzle parallel to the first stick
-
Set the nozzles symmetrically on both sides
-
Turn the sprayer on and check the nozzle direction
-