PAGE 28
OCT-16
Nozzle settings
•
Divide the spraying heights defined before, with the nozzle number and mark the parts
with the tape on the measure stick.
•
Direct the nozzles to the marked spots:
-
Put the stick for the nozzle setting on the nozzle and on the mark on the
measure stick the turn the nozzle parallel to the first stick
-
Set the nozzles symmetrically on both sides
-
Turn the sprayer on and check the nozzle direction
-
Mark the nozzle direction on the sprayer
Optical setting and changing the spraying height
-
Put the sprayer in to the plantation with the highest trees
-
Check the height and the spraying direction (with the eyes)
-
Put the sprayer in to the plantation with the lowest threes
-
Close the nozzles that you do not need (symmetrical left- right) to adopt to the height
-
Check again the spraying height
Check sprayer before each spraying season on its dosage and distribution
accuracy.
15. PREPARING THE SPRAYER FOR LOW TEMPERATURES
For low temperatures, you must prepare the sprayer (under 0 degrees C- stored outside) so
that cannot be damaged because of frost.
Hoses
Check the hoses for damages, make sure that they are not squeezed or folded.
Replace the hoses that are in bad condition.
Nozzles
Dismantle and check the nozzles, filters… If necessary, replace.
Frame
Some protection agents are very aggressive and the frame can rust. Remove all rust
and paint the damaged parts.
Residues of protection agents can cause explosion when combining with
organic substances and subjected to critical temperatures during repair
work (e.g., welding, grinding, filing) Prior to repair or welding on the frame,
all remnants of pesticides must be thoroughly cleaned to remove.
WARNING !
WARNING !