OCT-16
PAGE 35
18. NOZZLE HOLDER
The sprayer has a standard double-nozzle holder with a membrane valve and ceramic nozzles.
Every nozzle holder has tree spraying positions; if you turn it for 90
°
, the nozzle is closed.
You can clean the nozzle if you unscrew the nut. When putting together consider the line up.
When to replace or clean the nozzle?
- When we consume too much fluid according to the flow tables.
- When one nozzle is deviating from others.
- When the spraying angle is not uniform.
Cleaning and maintaining the nozzles
The nozzles are made from oxide ceramic and are very resistant to usage, but they
must be cleaned with a brush (toothbrush) and clean water or alcohol. Do not use
sharp objects for cleaning and do not let them fall.
The membrane valves must be changed when the fluid is dropping more than 10
seconds after closing the main valve.
Even small damages can change the spraying picture.
Do not turn the nozzle holders when pressure is in the system.
19. FAN DRIVE
The fan is driven by P.T.O. and a 2 - gear gearbox,
with idle run. The first gear is suitable for normal
work, the second gear is usually switched on in case
of bigger row widths. In case that You can’ t turn the
gear switcher, then you have to turn the P.T.O. by
hands in order to move the transmission
WARNING !